PSU 5000 / PSG 3000
Instructions for Assembly and Operation
Activation/deactiva--
tion of the inverter
1070 078 224--108
12---1
12 Activation/deactivation of the inverter
PSU
inverter ready
1
10
X5
1
8
X21
`
Activation of the inverter
1. Apply mains voltage
The inverter starts up. After approx. 10 s the DC link circuit is charged to re-
ach its maximum voltage, and the green LED ”inverter ready” lights up.
WARNING!
Danger of life through contact with live parts!
In this moment, the inverter is energized!
If the inverter housing is to be opened, switch off the system and wait for at least 5
minutes until the inverter is de--energized.
`
Deactivation of the inverter
1. When the supply has been switched off, the bridge rectifiers are blocked,
and the DC link is being discharged.
WARNING!
Danger of life through electrical voltage!
If the inverter housing is to be opened, switch off the system and wait for at least 5
minutes until the inverter is de--energized.
!
!
Summary of Contents for PSG 3000 Series
Page 1: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation MF Welding Inverters 109 Version ...
Page 3: ......
Page 5: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation 1070 078 224 109 ...
Page 97: ...PSU 5000 PSG 3000 Connection Instructions for Assembly and Operation 1070 078 224 109 11 18 ...
Page 101: ...PSU 5000 PSG 3000 Maintenance Instructions for Assembly and Operation 1070 078 224 108 13 2 ...
Page 105: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Accessories 1070 078 224 108 14 4 ...
Page 113: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Index 1070 078 224 109 17 4 ...
Page 114: ...1070 078 224 109 98 10 GB MBA AT VWS Printed in Germany ...