PSU 5000 / PSG 3000
Instructions for Assembly and Operation
Adjustment
functions
1070 078 224--- 109
9--3
9.3 Adjustment of PSU 5200 to the welding transformer
PSU 5200 with
PSG 3200.00 A
On Off
S1
1
2
3
4
5
6
7
8
On Off
S1
1
2
3
4
5
6
7
8
PSU 5200 with
1 x PSG 3100.00 A
On Off
S1
1
2
3
4
5
6
7
8
PSU 5200 with
2 x PSG 3100.00 A
9.4 Diode change--over
This function serves for the adjustment of diode monitoring
On Off
S1
1
2
3
4
5
6
7
8
Off : diode type SKN 4000
On : diode type SKN 6000
Selection of diode type in use
Parallel connection of diodes: OFF position
no parallel connection: ON position
For the switch settings for the different PSG types
please refer to Section 9.2 (for PSU 5100 / 5300)
or Section 9.3 (PSU 5200).
9.5 Selection of the control mode
For a description of the options, please refer to Section 8.
On Off
S1
1
2
3
4
5
6
7
8
Control by 5 kHz firing pulses: OFF position
Control by analog and weld time signal: ON position
Summary of Contents for PSG 3000 Series
Page 1: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation MF Welding Inverters 109 Version ...
Page 3: ......
Page 5: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation 1070 078 224 109 ...
Page 97: ...PSU 5000 PSG 3000 Connection Instructions for Assembly and Operation 1070 078 224 109 11 18 ...
Page 101: ...PSU 5000 PSG 3000 Maintenance Instructions for Assembly and Operation 1070 078 224 108 13 2 ...
Page 105: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Accessories 1070 078 224 108 14 4 ...
Page 113: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Index 1070 078 224 109 17 4 ...
Page 114: ...1070 078 224 109 98 10 GB MBA AT VWS Printed in Germany ...