43.4.3 General (LBB4433/00)
figure 43.23: Configure call station, step 3
table 43.11: General configuration settings (LBB4433/00)
Item
Value
Description
Class
Normal
Emergency
Sets the priority range of the call station. This is either
Normal
for 32 to 223 or
Emergency
for 32 to 255. When
Class
is
Emergency
the call station can make fail-safe calls.
Clear selection after call
Yes
No
Selects whether selections that are made on a keypad for a call
(zone selection, priority selection, tone selection and message
selection) will be cleared after the call has finished or will be
kept for a next call.
Network power
supervision
On
Off
When
Network power supervision
is
On
and the network
power is failing, a fault event is generated.
Back-up power
supervision
On
Off
When
Back-up power supervision
is
On
and the back-up
power is failing, a fault event is generated.