OD850 Outdoor

TriTech 

®

 Detector

Specifi cations

Dimensions:

6.5 in. x 3.25 in. x 2.25 in. 
(16.5 cm x 8.25 cm x 5.7 cm)

Input Power:

10 VDC to 15 VDC @ 22 mA 
standby. Maximum current 62 mA. 
Use only a Listed limited-power 
source.

Standby 
Power:

No internal standby battery. 
Standby power must be provided 
by a Listed limited-power source. 
For UL Certifi cated installations, 
4 h (88 mAh) standby power must 
be provided by the control panel or 
by a Listed burglary power source.

Alarm 
Relays:

Form “A” normally closed (NC), 
supervised alarm contact opens 
on alarm. Form “C” unsupervised, 
timed relay contact transfers on 
alarm and follows an installer 
programmable timer.

Contact 
Ratings:

2.5 W, 100 mA maximum, 25 VDC 
maximum, ,20 Ohms closed. 

Note:

 For resistive loads only, do 

not use with capacitive or inductive 
loads.

Temperature 
Range:

The temperature range is -31°F 
to +140°F (-35°C to +60°C) for 
all installations including UL 
Certifi cated installations. 

Microwave 
Frequency:

OD850-F1: 10.525 GHz (UL 
Listed)
OD850-F2: 10.588 GHz

Coverage:

50 ft by 50 ft (15 m by 15 m)

Tamper:

NC (with cover on). Contacts 
rated 125 mA maximum, 25 VDC 
maximum. Connect tamper circuit 
to a 24-hour protection circuit.

IP Rating:

54

Options:

B335 Low Profi le Swivel Mount 
Bracket (supplied), B328 Swivel 
Mount Bracket, B338 Ceiling 
Mount Bracket, Pole Mount 
Bracket (supplied). 

Note:

 Misaligning the detector in 

these brackets can reduce the 
detector’s range and increase the 
dead zone area.

Installation Considerations

Never install the detector where the PIR or microwave 
is in constant alarm (LED on). The LED is off when 
properly installed.

Point away from traffi c. 

Avoid installing where hanging signs, trees or other 
objects that the wind can move are within the coverage 
pattern or where wildlife might move within the 
coverage pattern.

The mounting surface must be solid and vibration-free. 

UL Listing Requirements

The unit shall only be installed outdoors for primary 
protection in high security installations where unwanted 
alarms would be tolerated. Otherwise, the outdoor 
device should be used for supplementary protection 
only, and be connected to a trouble zone or to a zone 
that is not programmed for off-premises transmission.

Warning!

Apply power only after all connections are made 
and inspected. Do not coil excess wiring inside 
detector.

Do not connect any terminal to any power supply 
providing more than 25 VDC.

SELV

Connect all wiring to a Safety Extra-Low Voltage (SELV) 
circuit only.

Coverage Patterns

 Microwave coverage  

 PIR coverage

 Look-down zone

Note:

 When choosing the appropriate mounting height 

for your application (particularly, when the terrain is not 
level) the upper fi nger is the strongest and responds 
more quickly to an intruder’s presence. Every fi nger 
shown in the top view (3-1) has the same side view 
(3-2) confi guration.

Mounting 

1.  Select a mounting location. Mount the sensor where an intruder is most likely to cross the coverage pattern.

2.  Mount the detector 7 ft to 9 ft (2.1 m to 2.7 m) above the ground. Recommended: 7 ft (2.1 m)

Note:

 Mounting height recommendations are based on level surfaces. If the terrain is not level, adjust the 

mounting height and detector angle to provide the best coverage.

3.   Slide the mounting plate down (4-1) until you hear a click, and remove it from the cover.

4.   Mount the mounting plate using one of these options:

Note: 

Do not remove the waterproof label from the mounting plate (4-2). Push the mounting screws or wiring 

knockouts through the label as needed.

Surface mount using a single-gang electrical box.

1.  Install a single-gang electrical box at the detector location.

2.  Attach the mounting plate (4-3) to the single-gang box with the appropriate screws. 

Surface mount without an electrical box.

1.  Select an appropriate location.

2.  Using the mounting plate (4-1) as a template, mark the location of the mounting screws and the wire run. 

3.  Attach the mounting plate (4-1) to the wall with the appropriate screws. 

Surface Mount using the supplied B335 Bracket or an optional bracket. Use the bracket’s instructions to 
attach the bracket to the appropriate mounting surface.

Attach the B335 Bracket to the mounting plate. (4-4).

Attach the B328 Bracket to the mounting plate. (4-5).

Attach the B338 Bracket to the mounting plate. (4-6).

Pole Mount using the supplied bracket.

Note:

 Do not mount to fence posts that might sway in the wind. 

Attach the bracket (4-7) to the mounting plate (4-8) using the appropriate screws and mounting 
holes.

Two hose clamps (not supplied) large enough to fi t around the pole are recommended for fastening 
the detector mounting plate to the pole.

Tamper Options

The unit has a built-in cover tamper that signals when 
the detector unit (4-9) separates from the 
mounting plate (4-1). The unit can also be installed so 
the tamper signals if the entire unit is pulled away from 
the surface on which it is mounted.

Note:

 The wall and cover tamper option are only 

available when the unit is surface mounted. The cover 
tamper is available with all mounting options.

Determine whether the tamper switch is to be used as 
a cover tamper or a wall and cover tamper:

Wall and cover tamper:  Use the appropriate 
screw to fasten the mounting plate tamper section 
(5-1) to the wall.

Cover tamper: Do not attach the mounting plate 
tamper section (5-1) to the wall.

Terminal

Label

Function

(-)

Input power: Use at least a 
22 AWG (0.8 mm) wire pair 
between the unit and the 
power source.

2

(+)

3 NC

Alarm 

relay 

4

C

5

T

Tamper

6

T

7

NC

Timed alarm relay contacts

8 C
9

NO

CAUTION!

Only apply power after all connections have been 
made and inspected.  Do not coil excess wiring inside 
detector. Use no smaller than #22 AWG (0.8 mm) wire 
in the terminal strip. 

Wiring

DIP Switch Confi guration

(7-1) On
(7-2) Off

Switch

Feature

Description

Switch Position

0

LED 
Disable

Determines if the LED lights during 
alarm situations. 
Default factory setting: ON

ON:

 LED enabled 

OFF:

 LED disabled 

1

PIR 
Sensitivity

Standard:

 Minimizes false alarms.

Tolerates environmental extremes 

Intermediate:

 Use where an intruder 

might cover only a small portion of the 
protected area. 
Tolerates normal environments. 

Note:

 The detector is shipped in 

Standard Mode.

ON:

 Standard

 

OFF

: Intermediate

2 and 3

Timed 
Relay 
Outputs

Form “C,” unsupervised, timed relay 
contact that transfers 1 sec after an 
alarm. It follows a user-selectable 
timer. The time expires at the time set 
after the last alarm. It resets on each 
new alarm. 

SW2

SW3

Relay Activation Time

OFF

OFF

2 sec

ON

OFF

1 min

OFF

ON

5 min

ON

ON

10 min

4

AND/OR 
Mode

Determines if the detector alarms 
in the AND mode (when both 
technologies simultaneously sense an 
alarm condition) or in the OR mode 
(when either the PIR or Microwave 
technology senses an alarm state). 

Note:

 The OR mode is 

not 

recommended for most installations. 
The OR mode provides faster 
detection in some conditions. It 
can also increase the likelihood of 
nuisance alarms because the detector 
activates the alarm relay based on 
input from a single technology.

ON:

 AND Mode (recommended)

OFF:

 OR Mode, you must also cut the 

jumper (4-10).

NOTE

OR Mode is not compliant with 
EN50130-5

5

Not used

6

Not used

LED Display

LED Indicator

Condition

Green

Steady

PIR alarm

Flashing

Microwave alarm

Red

Steady

Dual alarm (both technologies)

Flashing

Power-up

Attaching Detector to Mounting 
Plate

1.  When all wiring is connected to the detector but not 

to the power supply and all the settings are made, 
slide the detector unit (4-9) onto the mounting plate 
(4-1) and down until it is fi rmly seated. Avoid 
pinching the wires.

2.  With a small fl at head screwdriver, turn the locking 

cam (9-1) 180

o

 to lock (9-2) the detector unit to the 

mounting plate. Avoid excessive force.

Walk Test

Note: 

Ensure the detector is fastened to the mounting plate and all wiring is connected and powered before 

beginning the Walk Test.

Note:

 Ensure the LED Disable (SW0) is on (refer to 

Section 7 DIP Switch Confi guration

).

Note:

 To avoid false alarms, set the microwave range (10-1) to its minimum setting before starting the Walk Test.

 Microwave coverage

 PIR coverage

1.  Wait at least 2 minutes after power up to start the 

Walk Test. 
The LED fl ashes red until the detector stabilizes and 
no movement is detected for 2 seconds.

2.  Watch the LED as you walk towards the edge of the 

pattern (10-2). The LED lights at the outside edge of 
the coverage range.

3.  Repeat Step 3 from different directions until you 

adequately verify the coverage pattern.
The green LED lights, identifying the PIR pattern 
edge.
The green LED fl ashes, identifying the microwave 
pattern edge.

4.  Repeat Step 3 from the opposite side.

5.  If the required range is not achieved, increase the 

microwave adjustment (10-1) by turning it clockwise 
slightly.

6.  Repeat the walk test and adjustments until you 

reach the farthest edge of coverage needed.

Note:

 This equipment has been tested and found to 

comply with the limits for a Class B digital device, 
pursuant to part 15 of the FCC rules.  These limits are 
designed to provide reasonable protection against 
harmful interference in a residential installation.  This 
equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful 
interference to radio communications.  However, there 
is no guarantee that interference will not occur in a 
particular installation.  If this equipment does cause 
harmful interference to radio or television reception, 
which can be determined by turning the equipment 
off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:

 

-

Reorient or relocate the receiving antenna.

 

-

Increase the separation between the equipment 
and receiver.

 

-

Connect the equipment into an outlet on a 
circuit different from that to which the receiver is 
connected.

 

-

Consult the dealer or an experienced radio/TV 
technician for help.

This device complies with Part 15 of the FCC Rules. 
Operation is subject to two conditions:
1.  

This device cannot cause harmful interference.

2. 

This device must accept any interference 
received, including interference that might cause 
undesired operation.

Changes or modifi cations not expressly approved 
by Bosch Security Systems, Inc. can void the user’s 
authority to operate the equipment.

Compliance

EN 50130-5 Environmental Class II
IP30 IK04 (EN 60529, EN 62262)

N663

This product is intended for use in the following 
countries within the European Union and in other 
countries outside of the European Union:
OD850-F1: Austria, Belgium, Denmark, Finland, 
Greece, Luxembourg, Netherlands, Norway, Spain, 
Sweden, Italy
OD850-F2: France, United Kingdom

Summary of Contents for OD850 Outdoor

Page 1: ...eite 6 Istruzioni di installazione del rilevatore a infrarossi passivi e del rilevatore a microonde antintrusione per esterni OD850 Pagina 7 Instruções de instalação do detector contra intrusos por Microondas Infravermelhos passivos OD850 Exterior Página 8 Instrucciones de instalación del detector de intrusión por infrarrojos pasivos microondas para exterior OD850 Página 9 OD850 户外被动红外线探测器 微 波入侵探测...

Page 2: ...Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 9199 www boschsecuritysystems com 2012 Bosch Security Systems Inc F01U263662 02 Page 2 of 10 9 10 7 1 7 2 7 9 1 9 2 10 1 10 2 ...

Page 3: ...cover tamper or a wall and cover tamper Wall and cover tamper Use the appropriate screw to fasten the mounting plate tamper section 5 1 to the wall Cover tamper Do not attach the mounting plate tamper section 5 1 to the wall Terminal Label Function 1 Input power Use at least a 22 AWG 0 8 mm wire pair between the unit and the power source 2 3 NC Alarm relay 4 C 5 T Tamper 6 T 7 NC Timed alarm relay...

Page 4: ...e bevestigingsplaat 4 4 Bevestig de B328 arm op de bevestigingsplaat 4 5 Bevestig de B338 arm op de bevestigingsplaat 4 6 Bevestig op de staaf met behulp van de meegeleverde arm Opmerking Niet op hekpalen plaatsen die in de wind kunnen bewegen Bevestig de arm 4 7 op de bevestigingsplaat 4 8 met behulp van de daarvoor bestemde schroeven en bevestigingsgaten Twee slangklemmen niet meegeleverd die gr...

Page 5: ...a plaque de montage 5 1 au mur Autoprotection capot Ne fixez pas la partie autoprotection de la plaque de montage 5 1 au mur Câblage Borne Indication Fonction 1 IAlimentation Utilisez au moins une paire de fils de 22 AWG 0 8 mm entre l appareil et la source d alimentation 2 3 NC Relais d alarme 4 C 5 T Autoprotection 6 T 7 NC Contacts de relais d alarme temporisés 8 C 9 NO 7 1 On 7 2 Off Configura...

Page 6: ...n der Wand Deckelsabotageschutz Befestigen Sie den Sabotageschutzabschnitt 5 1 der Montageplatte nicht an der Wand Sabotageschutzoptionen Verdrahtung Klemme Etikett Funktion 1 Eingangsleistung Wenigstens ein 0 8 mm dickes Drahtpaar zwischen dem Gerät und der Stromquelle verwenden 2 3 NC Alarmrelais 4 C 5 T Sabotageschutz 6 T 7 NC Alramrelaiskontakte mit Zeitschalter 8 C 9 NO 7 7 1 On 7 2 Off Schal...

Page 7: ...amper a coperchio non collegare la sezione del tamper della piastra di montaggio 5 1 alla parete Opzioni del tamper 6 7 7 1 ON 7 2 OFF Configurazione dei DIP switch Cablaggio Morsetto Etichetta Funzione 1 Alimentazione utilizzare una coppia di cavi di almeno 22 AWG 0 8 mm tra l unità e l alimentatore 2 3 NC Relè di allarme 4 C 5 T Tamper 6 T 7 NC Contatti di relè di allarme temporizzati 8 C 9 NO S...

Page 8: ...a fixar o suporte à superfície de montagem adequada Fixe o suporte B335 à placa de montagem 4 4 Fixe o suporte B328 à placa de montagem 4 5 Fixe o suporte B338 à placa de montagem 4 6 Montagem em poste utilizando o suporte fornecido Nota Não monte em postes de vedações que possam oscilar com o vento Fixe o suporte 4 7 à placa de montagem 4 8 utilizando os parafusos e orifícios de montagem adequado...

Page 9: ...e la sección de bucle de antisabotaje de la placa de montaje 5 1 a la pared Opciones de bucle de antisabotaje 6 Conexión Terminal Etiqueta Función 1 Alimentación utilice un par de cables de por lo menos 22 AWG 0 8 mm entre la unidad y la fuente de alimentación 2 3 NC Relé de alarma 4 C 5 T Bucle de antisabotaje 6 T 7 NC Contactos de relé de alarma con temporizador 8 C 9 NO 7 7 1 Ecendido 7 2 Apaga...

Page 10: ...感开关会发出信号 备注 只有在装置安装在平面时 才能使用壁式和盖板 动态传感选用开关 盖板动态传感开关可提供各种安装 选项 确定是将动态传感开关用作盖板动态传感开关还是用作壁 式和盖板动态传感开关 壁式和盖板动态传感开关 用适当的螺钉将安装盘 动态传感开关部位 5 1 固定在墙上 盖板动态传感开关 请勿将安装盘动态传感开关部 位 5 1 固定在墙上 6 布线 终端 标签 功能 1 输入功率 在装置和电源之 间至少使用一对22 AWG 0 8 mm 电线 2 3 NC 警报继电器 4 C 5 T 动态传感 6 T 7 NC 定时警报继电器接点 8 C 9 NO 7 DIP开关配置 7 1 打开 7 2 关闭 开关 功能 说明 开关位置 0 LED禁用 确定在发出警报的过程中LED是否亮起 工厂默认设定值 打开 打开 LED启用 关闭 LED禁用 1 PIR敏感度 标准 最大限度减少错误警报 ...

Reviews: