F 002 DG9 A00
2013-04-16
|
Bosch Limited
�2 | N�� ���� | Commissioning
en
4.5
Gas selection
¶
Turn the toggle switch to "
Air
" or "
Nitrogen
".
4.5.�
Digital input
If the filling hose is connected to the digital port
(Fig. 2, Pos. 8, 10), the selected gas (air or nitrogen)
passes via the manifold (Fig. 3, Pos. 2) and then to the
vehicle tire. The pressure is monitored by the pressure
sensor and the value is displayed on the LCD.
4.5.2
Direct input
If the filling hose is connected to the direct port
(Fig. 2, Pos. 9), the selected gas (air or nitrogen) by-
passes the manifold (Fig. 3, Pos. 2). Hence, the pres-
sure is not monitored by the pressure sensor. The tire
pressure has to be manually checked.