F 002 DG9 A00
2013-04-16
|
Bosch Limited
�4 | N�� ���� | Program description
en
6.
Program description
6.�
Overview of operation
The following functions are available in the software:
R
Initiate nitrogen generation
R
Tire inflation and deflation
R
Tire inflation counter
R
Software update
6.2
Main menu
Menu option
Function
�NFL
Start tire inflation
DEFL
Start tire deflation
D�AG
R
Initiate calibration of pres-
sure sensor to atmospheric
pressure
R
Check status of the
NTI 1000
COUN�
View number of tires filled
i
The
COUN�
option displays the number of tires filled
only if the initial pressure difference during inflation
is greater than 10 Psi.
6.�
�nitiating nitrogen generation
After the NTI 1000 is powered on, nitrogen generation
starts automatically.
¶
To manually stop the nitrogen generation, press the
z
key
.
"
The message
CMS solenoid valves OFF
is dis-
played on the LCD.
¶
To start the nitrogen generation again, press the
v
key.
"
The message
CMS solenoid valves ON
is displayed
on the LCD.
i
To switch on the CMS valves, press
�
(Inflate) or the
v
key. To switch off, press the
z
key.
6.4
�ire inflation
i
Observe the tank pressure. It should be 10 bar. If the
pressure is lower, wait till the pressure reaches 10
bar.
i
Usually the filling pressure is mentioned beneath
the front door handle beside the driver's seat of the
vehicle. Open the front door and observe the filling
pressure. Else, refer to the vehicle user's manual.
1.
Select nitrogen or air inflation using the selector
switch.
2.
In the main menu, press
�
.
i
To change the unit between
Bar or PS�,
press the
UN��
key.
3.
Connect the filling nozzle to the tire.
4.
Press
Enter
.
Hold the filling nozzle to the tire until the set pres-
sure is reached. After the set pressure is reached,
a long beep is heard and the red LED glows.
5.
Remove the filling nozzle and connect it to the next
tire.
"
The tire inflation resumes automatically within 15
seconds without pressing the
EN�ER
key. To stop tire
inflation, press
Abort
.
6.5
�ire deflation
1.
In the main menu, press
2
.
2.
Select the required deflation option.
i
If
Normal
is selected, the tire is deflated till atmo-
spheric pressure. If
Vacuum
is selected, the tire is
deflated till 800 mbar.
i
It is recommended to select the option
Vacuum
only
if the vacuum pump is mounted. If the vacuum pump
is not mounted and the option
Vacuum
is selected,
the tire is deflated only till atmospheric pressure.
3.
Connect the filling nozzle to the tire.
4.
Hold the filling nozzle till the tire gets deflated.
After the set pressure is reached, a long beep is
heard and the red LED glows. The message
TIRE
DEFLATION COMPLETED
is displayed on the LCD.
The main menu is displayed.
5.
Remove the air filling connector and connect it to
the next tire. Repeat steps 1 to 4 for all the tires. To
stop tire deflation, press
Abort
.
6.6
�ire inflation counter
¶
In the main menu, press
4
.
"
The number of tires filled is displayed. After about 10
seconds the message is dismissed automatically and
the main menu is displayed.
6.7
Software update
Contact customer service for enquiries about software
updates.
Summary of Contents for NTI 1000
Page 1: ...NTI 1000 en Original instructions Nitrogen tire inflator ...
Page 2: ......
Page 19: ......