Product details | 85
•
Anti-seizing protection:
– The connected pump is monitored and exercised for a
short while after 24 hours of non-activity. This
prevents the pump from seizing.
– The connected mixing valve actuator is monitored and
run automatically for a short period after 24 hours of
non-activity. This prevents the mixer from seizing up.
A maximum of 6 MM100 modules are permitted in one system
irrespective of the number of other BUS nodes.
In the delivered condition, the code switch is in position
0
. The
module will only be registered in the user interface if the code
switch is in a valid position for the heating circuit or cylinder
primary circuit.
A system example with 3 heating circuits with mixing valves,
one heating circuit without mixing valve and one cylinder
primary circuit is shown in Fig. 21 on page 111. A further
example with 3 or more heating circuits and 2 cylinder primary
circuits is shown in Fig. 22 on page 112.
2.1
Importance usage notices
The module communicates via an EMS plus interface with other
EMS-plus-enabled BUS nodes.
•
The module must only be connected to user interfaces with
the EMS plus (Energy Management System) BUS interface.
•
The functional scope depends on the user interface
installed. Detailed information about user interfaces can be
found in the catalogue and technical guides and on the
manufacturer's website.
•
The installation space must be suitable for the IP rating
stated in the module specification.
2.2
Standard delivery
[1]
Module
[2]
Jumper for connection to MC1 if there is no temperature
switch in the assigned heating circuit (without mixer)
[3]
Bag with strain relief
[4]
Installation set flow temperature sensor
[5]
Installation instructions
2.3
Technical data
Design and operation of this product conform to
European Directives and the supplementary
national requirements. Its conformity is
demonstrated by the CE marking .
WARNING:
Risk of scalding!
▶ If DHW temperatures above 60 °C are set
or thermal disinfection is switched on, a
mixing valve must be installed at the DHW
outlet or at the DHW draw off points.
NOTICE:
Floor damage!
▶ Underfloor heating systems must only be
operated with an additional temperature
limiter (MC1 connection).
NOTICE:
System damage!
If a heating circuit is installed in conjunction
with a heat pump (heating/cooling),
condensate on cool system parts can lead to
damage.
▶ Only operate this heating circuit with dew
point monitor.
Technical data
Measurements
(W × H × D)
151 × 184 × 61 mm (further
dimensions
Maximum conductor
cross-section
•
230 V terminal
•
Extra-low voltage
terminal
•
2.5 mm
2
•
1.5 mm
2
Rated voltages
•
BUS
•
Module power supply
•
User interface
•
Pump and mixer
•
15 V DC (reverse-polarity-
protected)
•
230 V AC, 50 Hz
•
15 V DC (reverse-polarity-
protected)
•
230 V AC, 50 Hz
Circuit breaker
230 V, 5 AT
BUS interface
EMS plus
Power consumption
on – standby
< 1 W
Maximum output
•
Per connection (PC1
Pump Connection)
•
Per connection (VC1
Mixing Valve
Connection)
•
400 W (high-efficiency
pumps permissible; max.
40 A/
s)
•
100 W
Table 3
Summary of Contents for MM100
Page 105: ...6 720 808 907 2014 04 MM100 105 Fig 15 1 2 3 4 5 6 7 8 9 10 0 6 720 645 409 25 1O ...
Page 113: ...6 720 808 907 2014 04 MM100 113 ...
Page 114: ...6 720 808 907 2014 04 MM100 114 ...
Page 115: ...6 720 808 907 2014 04 MM100 115 ...
Page 116: ...Bosch Thermotechnik GmbH Sophienstrasse 30 32 D 35576 Wetzlar www bosch thermotechnology com ...