EN
GLISH
∅
3,
1
2,5
2
17
300
300
9,5
7
3
1
R320103169/2020-08
| Linear modules MKK/MKR-xxx-NN-3
Bosch Rexroth AG
23/62
Fig� 24:
Mounting the cable channel
6.7
Mounting the cable channel
Attaching cable channel to frame
1.
Measure the required length of the cable duct. Pay attention to the position of the switches and the socket.
2.
Saw off and deburr the cable channel.
3.
Create a recess to pass the cables through (
1
).
4.
If the existing fastening bores (
2
) are not sufficient (300 mm intervals), drill additional fastening holes into
the cable channel bottom (Ø 3.1 x 2.5 deep).
5.
Clip the cable duct into the slot at the linear module and screw on. Use the M3x8 bolts provided. For greater
clearance in the cable duct, use M3x8 set screws.
Inserting cables
f
Cut the cable grommets (
3
) open according to the diameter of the cables and insert them. (5 cable
grommets included).
f
Insert and wire the cables.
Mounting the cover strip with no cable channel end cover
f
Measure out, saw off, deburr, install and engage the cover strip for the cable duct.