Installation and connection
en
11
5
Installation and connection
Installation and connection
Do not install the appliance behind a decorative door
or the door of a kitchen unit, as this may cause the
appliance to overheat.
Electrical connection
Only licensed specialists may connect the appliance.It
is important that you comply with the requirements of
your electricity supplier.
Any damage arising from the appliance being
connected incorrectly will invalidate the warranty.
Caution!
Your appliance comes with the enclosed cable for
permanently connecting it to the mains electricity
supply.
Except in the event of damage, never remove the cable
from the appliance or replace it with another cable (with
or without plug).
Caution!
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
:
Warning – Danger of death!
There is a risk of electric shock if you touch live
components.
■
Always make sure your hands are dry when you
touch or hold the mains plug.
■
Only pull out the mains cable by taking hold of the
plug and removing the plug; never pull it out by the
mains cable itself, as this could damage it.
■
Never unplug the mains plug when the appliance is
in operation.
Please note the following information and ensure that:
Notes
■
The mains plug fits the socket.
■
The cable cross section is adequate.
■
The earthing system is properly installed.
■
The mains cable is only replaced by a qualified
electrician (if this is necessary).Spare mains cables
can be ordered from our after-sales service.
■
No power strips/multi-way connectors or extension
cables are used.
■
If using a residual current device, only use one that
bears the mark
z
.
The presence of this mark is the only way to be sure
that it fulfils all the applicable regulations.
■
The mains plug can be accessed at all times.
■
The mains cable is not kinked, crushed, modified or
severed.
■
The mains cable does not come into contact with
heat sources.
For the after-sales service
Caution!
■
The appliance must be connected in accordance
with the data on the rating plate.
■
Only connect the appliance to an electrical
connection that meets the applicable provisions. The
socket must be easily accessible so that you can
disconnect the appliance from the electricity supply
if necessary.
■
Please ensure the availability of a multi-pin
disconnecting system.
■
Never use extension cables or multiple plugs.
■
For safety reasons, this appliance must only be
connected to an earthed connection. If the safety
earth terminal does not comply with regulations,
safety against electrical hazards is not guaranteed.
■
An all-pole isolating switch with a contact gap of at
least 3 mm must be present in the installation circuit.
This is not necessary if the appliance is connected
by a plug that is accessible to the user.
■
Electrical safety: The cooker corresponds to safety
class I and may only be used in conjunction with a
safety earth terminal.
■
You must use a H 05 W-F type cable or equivalent
for the appliance connection.
The mains voltage must correspond to the voltage
specified on the rating plate.
Caution!
All appliances with a three-wire cable must be
earthed.
Connect the wires in the power cord according to the
colour coding:
Note:
If the power cord is replaced
Only connect it to the appliance as shown in the
connection diagram.
Removing the appliance
Disconnect the appliance from the mains power supply.
:
Warning – Risk of electric shock !
When disconnecting the appliance from the mains, the
connections may cause residual voltages. Only allow a
professional to connect the appliance.
Levelling the cooker
Always place the cooker directly on the floor.
The cooker has height-adjustable feet. This allows you
to raise the plinth by about 15 mm. Please observe the
special installation instructions.
Adjacent units
Any adjacent units must not be made of flammable
materials. The fronts of any adjacent units must be heat-
resistant up to at least 90 °C.
Explanaions
Green and yellow
earth wire
<
Blue
(null) neutral wire
Brown
phase (external conductor)
Summary of Contents for HLS79R350A
Page 2: ......