7 FAULT
DIAGNOSTICS
7.1
Controller / module with display
Customer complaint
Cause
Remedial action
Running time too long
Alternating rinse technology, energy saving
Advise customer,
See Consumption rates
or
Alternate
rinsing technology
Component is not actuated
Triac on the module
does not switch properly, smoke traces
may be visible on the module
Before replacing the module, always measure
the connected consumers (valves, actuators, etc.).
Comply with safety instructions
Time skips
Washtecnic. Adjust the time in the display to the actual
wash step.
Advise customer. There are some factor that have
influence: water temperature, amount of utensils,
degree of dirt on the utensils…
202_58300000104305_ara_en_b – 02.11.a