To install the air shroud:
4
Place air shroud in the chassis. The air shroud fits behind the two fans closest to the
power supply.
Note: If a 16 DIMM (13.68" x 13") motherboard is used, it is necessary to use the optional
MCP-310-82502-0N air shroud.
See also:
–
Checking the air flow, page 20
Checking the air flow
After installing the air shroud we recommend checking the air flow.
To check the air flow:
1.
Make sure there are no objects to obstruct airflow in and out of the chassis. In addition, if
you are using a front bezel, make sure the bezel's filter is replaced periodically.
2.
Do not operate the system without drives or drive trays in the drive bays. Use only
recommended material.
3.
Make sure no wires or foreign objects obstruct air flow through the chassis. Pull all
excess cabling out of the airflow path or use shorter cables. The control panel LEDs
inform you about system status.
See also:
–
Installing the air shroud, page 19
–
System interface, page 10.
–
Installing the air shroud, page 19.
–
Rack installation, page 24.
Replacing the system fans
The system fans provide cooling for the chassis. These fans circulate air through the chassis as
a means of lowering the chassis internal temperature.
3.9
3.10
20
en | Chassis setup and maintenance
DIVAR IP 7000 2U
2013.09 | V2 | DOC
Installation Manual
Bosch Sicherheitssysteme GmbH