40
en | Maintenance
DIVAR IP all-in-one 7000 3U
2021.10 | V02 | DOC
Installation manual
Bosch Security Systems B.V.
To replace the power distributor:
1.
Turn off the unit and remove the plug from the wall socket or power strip.
2.
Remove all cable connections to the power supply from the motherboard, backplane, and
other components. Also, remove both power supplies.
3.
Locate the power distributor between the power supply and the fan row.
4.
Remove the three screws securing the power supply.
5.
Gently pull the power distributor from the chassis. Gently guide all the cables through the
power distributor housing.
6.
Slide the new power distributor module into the power distributor housing. Make that
you slide the cables through the bottom of the housing.
7.
Reconnect all the power cables, replace the power supply, and insert the plug into the
wall.
10.13
Service and repair
The storage system is backed by a 3-year warranty. Issues will be handled according to Bosch
Service and Support guidelines.
The storage equipment is shipped with an original manufacturer Service and Support
agreement.
The Bosch Technical Support is the Single Point of Contact in case of failure but the Service
and Support obligations are fulfilled by the manufacturer or a partner.
In order to enable the manufacturer's Service and Support organization to fulfill the defined
Service Levels, the system must be re-registered. Otherwise, the defined service level cannot
be provided but only best effort.
A description what information is required and where to send is included in each shipment as
paper work. The description is also electronically available in the Bosch online product
catalog.