DIVAR IP all-in-one 7000 3U
Maintenance | en
33
Bosch Security Systems B.V.
Installation manual
2021.10 | V02 | DOC
10.3
Removing the chassis cover
1
1
2
2
3
1
Fixing screws
3
Chassis cover
2
Release tabs
To remove the chassis cover:
1.
Disconnect the power supply, lay the chassis on a flat surface.
2.
Remove the two screws on each side of the cover, which secure the cover to the chassis.
3.
Press the release tabs to remove the cover from the locked position. Press both tabs at
the same time.
4.
Once the top cover is released from the locked position, slide the cover toward the rear
of the chassis and lift the cover off the chassis.
i
Notice!
Except for short periods of time, do NOT operate the server without the cover in place. The
chassis cover must be in place to allow proper airflow and prevent overheating.
10.4
Identifying a faulty SSD drive
The system provides tools for hard drive monitoring that are pre-installed on the system.
Use the Intel Rapid Storage tool to identify a faulty SSD drive, if the RAID 1 mirror that holds
the operation system partition is running in degraded mode.
To identify and replace SSD drives:
1.
Turn on the unit and log on as user BVRAdmin. The default screen is displayed.
2.
Double-click the
Intel Rapid Storage
icon on the screen.