![Bosch D7212GV3 Program Entry Manual Download Page 128](http://html.mh-extra.com/html/bosch/d7212gv3/d7212gv3_program-entry-manual_39294128.webp)
D7212GV3 |
Program Entry Guide | 7.0
SIA CP-01 Quick Reference
EN
| 128
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
7.0 SIA CP-01 Quick Reference
Table 35: Programming the Control Panels for SIA CP--01 Compliance
Prompt Name
Bosch Recommended Settings
for SIA CP-01 Compliance
Shipping Default
References
Phone #
(Prefix backup phone number with
Call Waiting disable command)
{Blank}
Page 8
Duress Type
Option 3
0 (disabled)
Page 30
Cancel Report
Yes
Yes
Page 31
A# Exit Dly Time
45 sec to 255 sec
60 sec
Page 32
A# Duress Enable
Yes
No
Page 33
A# Exit Restart
Yes or No
Yes
Page 43
A# Arm No Exit
Yes or No
Yes
Page 43
A# Two Man Rule
No No
Page
41
A# Early Ambush
No
No
Page 42
A# Exit Warning
Yes Yes
Page
43
A# Entry Warning
Yes
Yes
Page 44
A# Burg Time
1
6 min to 90 min
6 min
Page 36
A# Alarm Bell
1 to 128(64), A, B, C
A (on-board alarm output)
Page 70
CC# Entry Tone
Yes or No
Yes
Page 48
CC# Exit Tone
Yes or No
Yes
Page 49
CC# Abort Display
Yes or No
Yes
Page 50
CC# Cancel Display
Yes or No
Yes
Page 50
Master Arm Inst
{Blank} {Blank}
Page
55
Perimeter Instant
{Blank}
{Blank}
Page 55
L## Send Duress
[Blank] or E
E
2
Page
68
L## Disarm
[Blank] or E
E
2
Page 61
L## Passcode Disarm
[Blank] or E
E
2
Page
68
P## Entry Delay
30 sec to 240 sec
30 sec
Page 83
P## Alarm Abort
Yes or No
Yes
3
Page
90
Abort Window
15 sec to 45 sec
30 sec
Page 124
Passcode Length
3 to 6 digits
Disabled
Page 125
Swinger Count
1 to 2 trips
1 trip
Page 125
Remote Warning
Yes Yes
Page
125
Cross Point Time
5 to 255 sec
20 sec
Page 127
P## Cross Point
Yes or No
No
Page 89
1 The SIA allowed range is 1 min to 90 min. Must additionally comply with UL requirements, refer to section
A# Burg Time
.
2 L14 is the default duress user index.
3 The default for P## Alarm Abort is
No
for P3, P4, P5, and P22.