Control Panel 

D7212GV2

Release Notes for Version 7.07 

December 2007

Trademarks 

Molex

®

 is a registered trademark of Molex Incorporated. 

1.0 Requirements 

Table 1:  Required Handlers 

 

D5200 Handler 

Version 

Changes 

GV2MAIN 

1.03 

New handler for the GV2 Series Control Panels, version 7.07 and later 

RADXUSR1 

1.06 

Updated to support GV2 Series Control Panels 

RADXPNTS 

1.08 

Updated to support GV2 Series Control Panels, version 7.05 and later 

RADXSKED 

1.04 

Updated to support GV2 Series Control Panels 

GV2AUX 

1.03 

New handler for the GV2 Series Control Panels, version 7.07 and later 

9000MAIN NA 

Not compatible

 with the GV2 Series Control Panels 

RADXAUX1 

NA 

Not compatible

 with the GV2 Series Control Panels 

 

 

 

 

During the development of the GV2 Series 
Control Panels, some D5200 Handler 
version numbers were skipped. The 
following version numbers were not 
released. 

GV2MAIN v1.01 
RADXUSR1 v1.05 
RADXPNTS v1.07 
RADXSKED v1.03 
GV2AUX v1.01 

 

 

Table 2:  Supporting Literature for D7212GV2 

with Version 7.07 Firmware and Later 

 

Document Name 

Part Number* 

D7212GV2 Program Entry Guide

 

F01U003804-03

 

D7212GV2 Program Record Sheet

 

F01U003803-03 

D7212GV2 Operation and 
Installation Guide

 

F01U003805-02 

D7212GV2 Approved Applications 
Compliance Guide

 

F01U003806-02 

*  Older revisions have alphabetic revision identifiers (for 

example, F01U003804

B

) and do not provide information 

that supports version 7.05 and later firmware. 

 

 

 

Use Remote Programming Software 
(RPS) version 5.7 and later with this 
software version. 

To acquire an update for your D5200 
Programmer, call the Bosch Security 
Systems, Inc. Handler Update System, 
toll-free, at (800) 657-4584. Make a 
separate phone call for each handler.  

Use an analog telephone line with the 
D5200. The D5200 dials only pulses. 

Refer to 

Section 10 Updating Handlers

 in 

the 

D5200 Programming Manual

  

(P/N: 74-06176-000-B) for details on 
updating handlers. 

Refer to 

Table 3

 for the required ROM kit part 

number. 

Table 3:  ROM Kit Part Number 

 

Control Panel Model 

Part Number 

D7212GV2 

R20-7212V2-ROM 

Summary of Contents for D7212GV2

Page 1: ...07 RADXSKED v1 03 GV2AUX v1 01 Table 2 Supporting Literature for D7212GV2 with Version 7 07 Firmware and Later Document Name Part Number D7212GV2 Program Entry Guide F01U003804 03 D7212GV2 Program Record Sheet F01U003803 03 D7212GV2 Operation and Installation Guide F01U003805 02 D7212GV2 Approved Applications Compliance Guide F01U003806 02 Older revisions have alphabetic revision identifiers for e...

Page 2: ...nt corrupted data account codes for systems that communicate with BIS 2 0 Security Engine These changes are only compatible with BIS Security Engine v2 1 1271 or later This addresses the issues described in the BIS SEE and GV2 G Series Technical Service Note P N F01U073249 Changes made allow the Relay Latches on point fault option for the P Relay Response Type feature to reset when a passcode is e...

Page 3: ... is installed on the RPS workstation special software firewall settings might be required to allow outgoing traffic Refer to your firewall software for configuration information Any DX4020 or D9133TTL E used for enhanced communication to a central station receiver or with RPS over a network must be configured to use Datagram Mode 2 when the control panel firmware is version 7 06 and later Refer to...

Page 4: ...evice are now included when a test report is sent using COMMAND 41 or a sked Corrections enhance the reliability and performance of RPS network connection These corrections also decrease the delay in reporting a break in the Ethernet connection to the control panel s Network Interface Module within the time limits required by UL For UL 1610 Line Security formerly Grade AA Intrusion System installa...

Page 5: ... panel wide Communications Failure Relay output to activate when events in Route Groups 2 through 4 do not reach the central station Previously this relay output activated only on a communication failure for Route Group 1 2 5 Version 7 02 The Phone Line Supervision feature has improved accuracy in detecting the phone line The Modem IIIa2 product ID is changed to the same ID as the G Series control...

Page 6: ...ion This feature was updated to manage the control panel clock adjustments over a period of time instead of simply jumping to the new time This enhancement allows consistent execution of Skeds at their intended times When a TimeSync adjustment is in process the Time Date idle text display is modified with a or sign to indicate control panel time is increasing or decreasing to match the target time...

Page 7: ...ed Fire Bypass Trouble Annunciation The Fire Bypass warning display is modified to generate a Trouble warning tone that can be silenced with COMMAND 4 The trouble condition self clears when all bypassed fire points within the keypad s scope return to service This feature is always on and cannot be disabled Summary Fire Relay Options An option is added that changes the duration of the Panel Wide Su...

Page 8: ...s the Entry Delay starts If the system is not disarmed within the programmed time an Exit Error Alarm is generated This feature is always enabled and has no configuration parameters The alarm with an exit error event creates a new Modem IIIa2 message that the central station might need to add to their automation software Refer to Event 38 in the Modem IIIa2 Messages section of the Appendix in the ...

Page 9: ... after event transmission displays CANCEL RPT SENT on the keypad The burglary alarm cancel window duration is the time programmed in the A Alarm Bell prompt Duress Passcode Prompts Duress Type A Duress Enable L Send Duress A new duress option is available that allows any passcode with the L Send Duress permission set to Yes to always send a Duress Alarm event upon entry This feature allows the con...

Page 10: ...nd simplifies system operation Passcode Controlled Menus The system prompts a user to enter a passcode before viewing the keypad function list menu The system shows the user the menu options allowed according to the user s authority level Passcode controlled menus simplify system operation by providing a user with unique and pertinent options and information This feature is not intended for use on...

Page 11: ...lable The default values for the Bright Dim mode are Bright 10 and Dim 3 On the D1260 and D1260B Keypads when the Sensor Reset command COMMAND 47 is executed Call for Service appears erroneously for a brief time on the display This effect also occurs when the control panel reboots Change the Service Passcode User ID 0 factory default value when the ANSI SIA CP 01 required Passcode Length parameter...

Page 12: ...ccount are armed the keypads in those areas display the text programmed in the Area Acct Is On prompt The control panel is supposed to provide a way to alternately use the display text programmed in the Area is On prompt under the same conditions but this feature is not yet available When an invisible point is programmed with P RlyResp Type set to 2 Relay Latches the relay must be manually reset u...

Reviews: