3.1
Overview
Fig. 3
Appliance overview
3.2
Features and safety devices
Easy to operate and environmentally friendly
The heat pump has user interface with easy use menu keys for
ease of programming. The heat pump is also environmental
friendly as it transfers heat from the surrounding area into the
water.
Heating capacity
The unit absorbs ambient energy and releases the heat into the
water stored in the tank. If the ambient temperature is low, the
heating capacity of the heat pump will be reduced, but you can
still rely on the electric element for backup.
Thermal Cut Out (TCOs)
The water heater is equipped with one thermal cut out (TCO)
located above the heating element, in contact with the tank
surface. If for any reason the water temperature becomes
excessively high, the thermal cut-out (TCO) cuts the power
circuit to the heating element. Once activated, the TCO must be
reset manually. Resetting of the temperature limiting control
should be done by a qualified service technician.
Air inlet
Air outlet
User
interface
User
interface
cap
Tank
6720801244-03.1V
CAUTION:
The cause of the high temperature condition
must be investigated by a qualified service
technician and corrective action must be
taken before placing the water heater in