![Bosch Compress 3000 DW FO HP 270-1E 0 FOV/S Installation Instructions Manual Download Page 40](http://html.mh-extra.com/html/bosch/compress-3000-dw-fo-hp-270-1e-0-fov-s/compress-3000-dw-fo-hp-270-1e-0-fov-s_installation-instructions-manual_52813040.webp)
6 720 801 244 (2013/08)
Compress 3000 DW FO
40 | Display
7
Display
7.1
Fault display
Installation, maintenance and repairs may only be carried out by an authorised contractor. The following table lists the fault codes
and their remedies.
Display
Description
Solution
E01
Fault in the top storage tank temperature sensor
Notify authorised contractor
E02
Fault in the bottom storage tank temperature sensor
Notify authorised contractor
E03
Fault in the temperature sensor at the air inlet
Notify authorised contractor
E05
Not used
Notify authorised contractor
E06
Hold down setting keys longer than 30 seconds
Release keys
E07
Not used
Notify authorised contractor
E08
Not used
Notify authorised contractor
E09
Incorrect system purging
Water shortage during off-peak
Water shortage for long period (> 12h)
Notify authorised contractor
Reset the system
E10
Heating element faulty
Fault in the high limit safety cut-out
Adjusted temperature in the thermostat below the set
point temperature in the tank
Notify authorised contractor
E11
Fault in the fan
High pressure loss in the air ducts
Leak in refrigerant circuit
Fault in the compressor
Fault in the expansion valve
Fault in the dry filter
Start up after a long standby period at very low
temperatures
Reset the system and notify authorised contractor
Table 6
Fault codes