„Heat pump“ mode
In this mode, the main heat source used is the heat pump.
When the incoming air temperature is between 10 °C and 40 °C
the appliance will only use the heat pump cycle to heat up the
water.
In case the inlet air temperature is between 3 °C and 10 °C the
unit will only use the heat pump cycle to heat up the water if
during the heating period the water temperature does not drop
below 45 °C.
If the water drops below 45 °C the appliance will use the
electrical heater to increase the water temperature up to 55 °C
and after that it will return to the heat pump cycle.
Fig. 23
„Heat pump“ mode
The appliance will return to use the heat pump cycle when
water temperature reaches 55 °C.
„Combi“ mode
This mode uses two heat sources, depending on conditions:
the heat pump or the backup electric element.
Fig. 24
„Combi“ mode
If the water temperature inside the tank is less than 60 °C and
the incoming air temperature is between 3 °C and 40 °C, the
appliance will operate in the same way as in the Heat Pump
mode.
The electric heating element will be activated when these
conditions are not achieved.
5.6.2 „Prog“ function - Timetable operation programming
The „Prog“ function permits the heat pump to be programmed
for operation based on the desired timetable only.
Fig. 25
„Prog“ function
The „Prog“ function provides access to the following menus:
•
„P1“ period (days 1-5)
•
„P1“ period (days 6-7)
•
„P2“ period (days 1-5)
•
„P2“ period (days 6-7)
•
„P3“ period (days 1-5)
•
„P3“ period (days 6-7)
„P1“ period
The heat pump functions during the predetermined factory
times. No other type of alteration is possible:
Days 1 - 5: [00:00
06:00] and [16:00
19:00]
Days 6 - 7: [02:00
08:00]
Fig. 26
„P1“ period
„P2“ and „P3“ periods
The heat pump functions at times preset by the user.