6 720 801 244 (2013/08)
Compress 3000 DW FO
26 | Operation Instructions
„Anti-freeze“ function
The electric heating element is activated when the water
temperature in the tank reaches 5 °C. It is disconnected when
the water temperature reaches 8 °C.
5.5
Temperature set point
Time/Temperature Relationship in Scalds
5.6
„Main“ menu
Accessing the „Main“ menu
▶ Press the „menu“ key and hold it down for more than 3
seconds.
Fig. 21
Accessing the „Main“ menu
Accessing the „Main“ menu provides access to the following
functions:
•
Mode - „Heating modes“
•
Prog - “Timetable operation programming“
•
Leg - “thermal disinfection“
•
Set - “adjustments“
•
Purg - “purge”
•
Info - “information“
▶ Use the „+“ or „-“ keys to select the desired menu.
▶ Confirm using the „ok“ key.
▶ Exit by pressing the „ok“ key and hold it down for over 3
seconds.
5.6.1 „Mode“ function - heating modes
The „Mode“ function permits selection of 2 different heating
modes:
•
„Heat pump“ mode
•
„Combi“ mode
Fig. 22
„Mode“ function
The water temperature is factory-set at a
value of 60 °C, and is not changeable.
DANGER:
Scalding!
A hot water scald potential exists if the water
temperature is set above 50 °C. Children,
disabled, and elderly people are at higher
risk of being scalded.
▶ Always feel water temperature before
bathing or showering.
Time to produce a serious burn
Tempera
-ture
Aged persons/
children under 5 years
Adults
50 °C
2-1/2 minutes
More than 5 minutes
52 °C
Less than 1 minute
1-1/2 to 2 minutes
55 °C
About 15 seconds
About 30 seconds
57 °C
About 5 seconds
About 10 seconds
60 °C
About 2-1/2 seconds
Less than 5 seconds
62 °C
About 1-1/2 second
Less than 3 seconds
65 °C
About 1 second
About 1-1/2 seconds
68 °C
Less than 1 second
About 1 second
Table 5
6720646160-49.1V
menu
-
ok
+
> 3 s
6720646160-19.1V