Climate 5000 MS – 6720887246 (2018/04)
7
Specifications
5
Specifications
Number of units that
can be used together
Connected units
1-5 units
Compressor stop/
start frequency
Stop time
3 min or more
Power source voltage
Voltage fluctuation
within ±10% of
rated voltage
Voltage drop
during start
within ±15% of
rated voltage
Interval unbalance
within ±3% of
rated voltage
Table 3.
Unit: m
1 drive 2 1 drive 3 1 drive 4 1 drive 5
Max. length for all
rooms
40
60
80
80
Max. length for
one indoor unit
25
30
35
35
Max. height
different between
indoor and
outdoor unit
15
15
15
15
Max. height
different between
indoor units
10
10
10
10
Table 4.
When installing multiple indoor units with a single outdoor unit, ensure
that the length of the refrigerant pipe and the drop height between
the indoor and outdoor units meets the requirements illustrated in the
following diagram:
Outdoor unit
Indoor unit
Max. height difference
Indoor unit
15 m
15 m
10 m
Indoor unit
Fig. 3.
6
Outdoor Unit Installation
6.1
Outdoor Unit Installation Instructions
Step 1: Select installation location.
The outdoor unit should be installed in the location that meets the
following requirements:
f
Place the outdoor unit as close to the indoor unit as possible.
f
Ensure that there is enough room for installation and maintenance.
f
The air inlet and outlet must not be obstructed or exposed to strong
wind.
f
Ensure the location of the unit will not be subject to snowdrifts,
accumulation of leaves or other seasonal debris.
f
The installation area must be dry and well ventilated.
f
There must be enough room to install the connecting pipes and
cables and to access them for maintenance.
Strong wind
Strong wind
Fig. 4.
f
The area must be free of combustible gases and chemicals.
f
The pipe length between the outdoor and indoor unit may not exceed
the maximum allowable pipe length.
f
If possible,
DO NOT
install the unit where it is exposed to direct
sunlight.
f
If possible, make sure the unit is located far away from your
neighbours property so that the noise from the unit will not disturb
them.
f
If the location is exposed to strong winds (for example: near
a seaside), the unit must be placed against the wall to shelter it from
the wind. If necessary, use an awning. (See
Fig. 4 & 5
)
f
Install the indoor and outdoor units, cables and wires at least 1 metre
from televisions or radios to prevent static or image distortion.
Depending on the radio waves, a 1 metre distance may not be enough
to eliminate all interference.
Strong wind
Fig. 5.