Setting the address (ID) of the camera
To prevent faulty operations and malfunctions, each camera
must have an unique address (ID). The default setting is
0[ID001].
X0
X1
SW30
1
SW30
2
Table 6.5: Dome Camera ID Setting (Rotary Switches SW301, SW302)
Setting the protocol of the camera
Set the protocol setting, the baud rate, and the termination
setting of dip switch SW303, using the data in the tables below.
Note: The value marked * is the default setting.
No
1
No
2
Protocol
Off On Bosch OSRD*
Off Off Pelco-D/Pelco-
P
Table 6.6: Camera Protocol Setting (No. 1 & 2, Dip Switch SW303)
No
3
No
4
Baud Rate
(bps)
Off Off 2400
Off On 4800
On Off 9600*
On On 38400
Table 6.7: Camera Baud Rate Setting (No. 3 & 4, Dip Switch SW303)