Installation
4–2
1070 073 825-103 (02.04) GB
4.1
Installed Positions and Clearances
Housing:
Front panel:
Protection category IP 65
Aluminium housing:
Protection category IP 54
Weight:
approx. 18 kg
Installation
position:
vertical, 0
_
up to max.
"
45
_
inclination
Installation
type:
floor or suspended installation, sealed according to
IP 54.
.
Please remember that the front panel may become dirty more readily if
installed at an angle.
Install. position max.
"
45
_
incline
CPS21
Minimum 100 mm all–round
clearance for cooling required
100
100
"
45
°
100
"
45
°
Bottom
mounting
device
Top
mounting
device
100
100
100
D
Install the CPS21 control panel, ensuring that it can be operated ergono-
mically. In addition, the operator must be provided with a permanent and
unobstructed line of sight to moving machine parts!
D
To prevent reduced screen readability and additional thermal load, avoid
installation locations that are exposed to direct sunlight.
D
The LEDs on the front panel must not be obstructed or concealed.
D
To ensure there is sufficient ventilation space, provide an all-round mini-
mum clearance of 100 mm (see drawing).
D
Allow for connecting loops in all cable routings. Use drag chain qualified
cables. Provide strain relief for all cables.
D
Keep as far away as possible from sources of interference.
Summary of Contents for CPS21_3
Page 1: ...Antriebs und Steuerungstechnik CPS21_3 CPS21_4 Interface Conditions Industrial PC Edition 103 ...
Page 90: ...Display and Control Elements 7 18 1070 073 825 103 02 04 GB Notes ...
Page 100: ...Maintenance and Replacements 8 10 1070 073 825 103 02 04 GB Notes ...
Page 102: ...Spare Parts 9 2 1070 073 825 103 02 04 GB Notes ...