Safety Functions
3–8
1070 073 825-103 (02.04) GB
Enable Temp Control
If this checkbox is activated, the system temperature is monitored perma-
nently. If the system temperature is exceeded, the following warning is dis-
played:
After a temperature warning, the UPS program is reactivated. During this re-
activation period of about 2 seconds, voltage monitoring does not take place
although the battery pack is functioning correctly.
Disable Auto Power Off
The function ”Disable Auto Power Off” makes sense only during system
start-up or during software installation. Make sure that the checkbox is deac-
tivated during normal operation!
CAUTION
Loss of data!
If this checkbox is activated, a regular shutdown of the operating sy-
stem is not possible after a voltage breakdown. The CPS21_3 /
CPS21_4 shuts down immediately!
Info
Shutdown count
The displayed value shows how often the system was shut down by UPS, i.e.
how many charging cycles the battery has been subjected to. More details
regarding after how many charging cycles it is necessaary to replace the re-
chargebale batteries is contained in section 8.2.3.
Default Setting UPS
NT
With this button, the standard values of the dialog elements can be preset.
These are:
D
COM port:
COM4
D
Shutdown Delay Time:
30 sec
D
Accu Test (battery test): active
D
Temp Control:
active
D
Disable Auto Power Off: inactive
Summary of Contents for CPS21_3
Page 1: ...Antriebs und Steuerungstechnik CPS21_3 CPS21_4 Interface Conditions Industrial PC Edition 103 ...
Page 90: ...Display and Control Elements 7 18 1070 073 825 103 02 04 GB Notes ...
Page 100: ...Maintenance and Replacements 8 10 1070 073 825 103 02 04 GB Notes ...
Page 102: ...Spare Parts 9 2 1070 073 825 103 02 04 GB Notes ...