EM-RES-03
10/07
8
8 EM-RES-03
10/07
3 Technical data of the expansion module EM-RES-03
For usage of the expansion module comply with the technical data of the basic de-
vice.
Terminal X410A
Terminal X410B
X410A.1 DC-24 V output
(max. 180 mA)
1)
X410B.1 Not connected.
X410A.2 Ground 24 V
X410B.2 Digital input EM-S1IND
2)
X410A.3 Digital output EM-S1OUTD
2)
X410B.3 Digital input EM-S2IND
2)
X410A.4 Digital output EM-S2OUTD
2)
X410B.4 Digital input EM-S3IND
2)
X410A.5 Not connected.
X410B.5 System bus, CAN-Low
X410A.6 Analog input EM-S1INA
2)
X410B.6 System bus, CAN-High
X410A.7 Ground 10 V
X410B.7 Ground 10 V
1)
The power supply at terminal X410A.1 may be loaded with a maximum current of
I
max
= 180 mA. Relative to the application, the maximum current available will be
reduced by the further control outputs of the frequency inverter and expansion
module.
2)
The control electronics can be freely parameterized.
Resolver- and PTC-input X412 (SubD-9)
Resolver:
PTC
input
2)
Number of pole pairs: 1 … 7
Tripping resistance = 2.4 kΩ acc. DIN 44081
Input voltage 7 V
RMS
Hysteresis = 1.3 kΩ
Input frequency 8 kHz
Input current <= 60 mA
PTC thermistor respectively
U
in
/U
ref
= 0.5
bimetallic temperature sensor (normally closed
contact)
Warning!
The PTC input is not insulated. Only PTC thermistors with safe insulation
from the motor winding acc. to EN61800-5-1 may be connected.
Note:
BONFIGLIOLI servomotors of types BCR and BTD are designed with safe
insulation from the motor winding.
Technical data of the control terminals
Digital inputs
(X410B.2) … (X210B.4):
Low signal: 0 V … 3 V, High signal: 12 V … 30 V, Input resistance: 2.3 kΩ,
Response time: 4 ms, PLC compatible
Frequency signal: 0 ... 30 V, 10 mA at 24 V, fmax
= 150 kHz
Digital outputs
(X410A.3), (X410A.4):
Low signal: 0 V … 3 V,
High signal: 12 V … 30 V, output current: 40 mA, PLC compatible
Analog input
(X410A.6):
Analog signal: input voltage: -10 V … 10 V / 0 V … 10 V (R
i
= 100 kΩ),
Resolution 10 Bit
DC-24 V output
(X410A.1):
I
max
= 180 mA. This value can be lower dependent on the load at the digital outputs
of the basic device and expansion module.
Conductor cross section
:
Suitable cross sections of the control terminals are:
With wire end ferrule:
0.25…1.0 mm²
Without wire end ferrule: 0.14…1.5 mm²