Accessing data via PROFINET
40
Operating manual for PROFINET fieldbus | DOC01725815-0003 | 2016-12 | V2.04 EN
Continuation
PROFINET
DGM parameter
Slot
Index
Parameter
Number*
Accepted
Name in
German
Minimum
Maximum
Unit
2
132
388
33.015
1: Ready
R optimisation
0
200
%
2
147
403
33.016
1: Ready
Motor phase
monitoring
0
1
2
70
326
33.031
1: Ready
Motor current
0
150
A
2
71
327
33.032
1: Ready
Motor rating
50
55000
W
2
73
329
33.034
1: Ready
Motor speed
0
80000
rpm
2
74
330
33.035
1: Ready
Motor frequency
10
400
Hz
2
115
371
33.050
1: Ready
Stator resistance
0
100
Ohm
2
117
373
33.105
1: Ready
Scatter
inductivity
0
1
H
2
68
324
33.110
1: Ready
Motor voltage
0
1500
V
2
72
328
33.111
1: Ready
Motor cos phi
0.5
1
2
125
381
33.138
2: Always
Holding current
time
0
3600
s
2
116
372
33.200
1: Ready
Stator induc.
0
1
H
2
129
385
33.201
1: Ready
Nominal flux
0
10000
mVs
2
111
367
34.010
1: Ready
Control method
100
299
2
85
341
34.011
1: Ready
Type of encoder
0
2
1
2
86
342
34.012
1: Ready
Encoder line
count
0
10000
1
2
87
343
34.013
2: Always
Encoder offset
-360
360
°
2
131
387
34.020
2: Always
Flying restart
0
1
2
130
386
34.021
2: Always
Catch time
0
10000
ms
2
8
264
34.030
2: Always
Switching
frequency
1
4
2
121
377
34.090
2: Always
Speed controller
Kp
1
10000
mA/rad
/s
2
122
378
34.091
2: Always
Speed controller
Tn
0
10
s
2
113
369
34.110
2: Always
Slip trimmer
0
1.5
Continues next page