Bombardier Transportation (ZWUS) Polska Sp. z o.o.
4
TECHNICAL DESCRIPTION
4.1
Technical data
Parameter
Data
Remarks
Power supply
Primary power supply
voltage
230V (+10%, -15%) / 50 Hz
Power consumption:
Maximum
Average
1500W
300W
Stabilised power supply
DC/DC converters to
charge batteries
EMF-65 26-31 V DC
Manufacturer
BT ZWUS
Buffered power supply of
LX devices
Types of batteries
24 V DC, 2-4 batteries
24V/85Ah,
24V/115Ah,
24V/150Ah
e.g.
A512/85A
Time of normal system
operation in case of no
supply 230V/50Hz
min. 8h / 100 pairs of trains
Warning devices
LED Road signal:
- Flashing frequency
- LED unit
- Power consumption
EHZ-8
0,67Hz
EHE-2
4W per one LED unit
Manufacturer
BT ZWUS
Audible alarm:
- Supply voltage
- Pulse frequency
- Sound intensity
Sound generator EDG-40 and
loudspeaker EDE-1000
12V or 24V DC
1Hz ±20%
60÷80dB in the distance of 7m
Manufacturer
BT ZWUS
Electrical gate machine:
- Barrier boom length
- Supply voltage
- Type
EEG-1
<= 12m
24VDC
no self-falling
Manufacturer
BT ZWUS
Barrier boom:
- Length
ESD-8
3,5 – 6,5m
Manufacturer
BT ZWUS