EN
27
27
For energy-saving reasons, the display lighting will
switch off after approximately 60 seconds; however,
it can be switched on again by pressing or .
The Glass
Buddy
will switch off automatically after
about 10 minutes if no keys have been pressed.
Explanation of the Menu Items
The menu can be accessed via
;
allow you to select between the various
menu items:
SWITCH OFF
If the arrow
>
is in front of the menu item
Switch
off
, you can switch off the Glass
Buddy
by pressing
.
GLASS TYPE
If the arrows > < are in front of the menu item Glass
type, press after selecting in order to reach the
submenu. Here you can select the type of glass you
wish to analyse by pressing the keys
.
Confirm your selection with .
n
Not ISO glass (menu display:
not ISO
)
- for the analysis of single-pane glass up to
2.6 mm to 19 mm thick
- for the analysis of monolithic laminated
and laminated safety glass (lam and lam-
safety)
- for the analysis of monolithic laminated glass
(multi-lam), with the exception of fire
protection glass
Note: If you measure other glass types with this
setting, this can lead to erroneous
measuring results.
n
ISO glass (menu display: ISO)
- for the analysis of 1-gap insulating glass made
of 2 x monolithic glass
- for the analysis of 1-gap insulating glass with
laminated glass
- for the analysis of 1-gap insulating glass with
laminated safety glass
- for the analysis of 1-gap insulating glass with
multi laminated glass, with the exception of
fire protection glass
Note: If you measure other glass types with this
setting, this can lead to erroneous
measuring results.
n
ISO3 glass (menu display:
ISO3)
- for the analysis of 2-gap insulating glass made
of 3 x monolithic glass
- for the analysis of 2-gap insulating glass with
laminated glass
- for the analysis of 2-gap insulating glass with
laminated safety glass
Note: If you measure other glass types with this
setting, this can lead to erroneous
measuring results.
n
Not ISO fire protection glass*
(Menu display:
not ISO multi-lam
)
- for the analysis of monolithic multi
laminated glass (multi-lam) as fire protection
glass
Note: If you measure other glass types with this
setting, this can lead to erroneous
measuring results.
n
ISO with fire protection glass*
(Menu display:
ISO multi-lam
)
- for the analysis of 1-gap insulating glass with
multi laminated glass as fire protection glass
Note: If you measure other glass types with this
setting, this can lead to erroneous
measuring results.
The selected glass type setting is displayed in the
menu.
Note: The Glass
Buddy
will return to the default
settings once the device is switched off. When
switching it on again, you can analyse the glass
type again.
* only Glass
Buddy
Plus