Operating instructions for S 40-3...S 150-3 series screw compressors
Page 51
Maintenance
6.1
Safety instructions for maintenance
Part 6: Maintenance
6.1 Safety instructions for maintenance
WARNING!
Ensure that maintenance work is only carried out by qualified professionals
or appropriately trained persons.
– Prior to starting any maintenance work, always take the compressor out
of operation as described in these operating instructions before removing
any safety covers or safety devices. Refit the safety covers or safety de-
vices immediately after completion of the maintenance work.
– Heavy components may only be lifted up by various persons in due con-
sideration of the local industrial safety regulations.
– Only use original spare parts, compressor oils and operating materials
released by BOGE for the maintenance work.
– With an activated automatic restart (Auto-Restart) the compressor may
restart automatically after a voltage failure.
Prerequisite: The net pressure is lower than the set switch-on pressure.