Operating instructions for S 40-3...S 150-3 series screw compressors
Page 67
Maintenance
6.4
Maintenance work at fixed service intervals
Fig. 6.7: Change the oil separator
7. Lightly oil the sealing rings of the new oil separator.
8. Screw in new oil separators by hand.
9. Put the cover back on on the maintenance side
10.Open ball valve at the compressed air outlet.
11.Switch the compressor on and let it heat up until it reaches the operating
temperature.
12.Switch the compressor off with the OFF button.
13.Check the oil separator for leaks once again and tighten by hand if neces-
sary (procedure as described above).
Every 3,000 operating
hours / once a year:
Check V-belt
Check the V-belt:
– After 3,000 operating hours, but at least once a year to look for signs of
damage.
WARNING!
Do not use tools to screw in the new oil separators!
You might damage the oil separators or their sealing rings.
A hand tight seating of the oil separators is sufficient
WARNING: Risk of injury!
Press the emergency stop button, use the mains disconnection device to iso-
late the compressor from the power supply and fix a padlock to prevent the
power from being switched on again unintentionally.