BOGE FOCUS compressor control for piston compressors
Page 7
FOCUS
1.3
Display information
Maintenance
With the next actuation of the
-key
you get to the servicing display. Here the
information concerning the servicing times are displayed.
Operating times
By pressing the
-
key
you get to the operating times display. On this menu
page the operating times of the compressor are displayed.
Leakage monitor
Pressing the
key
in the operating hours display causes the control display
to show "leakage". The display serves to enable you to determine the energy
loss resulting from any potential leaks in your compressed air network.
To this purpose, the control unit measures the time period duration of the
operating loads during which, under normal circumstances, no production of
compressed air takes place, as for example over night or operation down-
times.
This, however, is conditioned on the fact that operational compressed air pro-
duction be discontinued for a protracted period of time and that the compres-
sor be set into the "ready" mode by means of the control system. In case of a
potential pressure reduction below the preset minimum pressure value result-
ing from leaks in the compressed air network, this compressor automatically
switches into the operating mode in order to recover the set -pressure range.
The leakage measurement serves to record the duration of the operating load
times and to extrapolate them for the whole year. This allows you to quantify
any leakages and to easily determine their portion of additional costs due to
any energy losses.
Next motor
servicing (h)
Shows the operating hours until the next motor servicing.
Next compressor
servicing (h)
Shows the operating hours until the next compressor servicing.
Next receiver
servicing
Shows the number of load changes until the next receiver serv-
icing.
Normally not used for piston compressors.
Current battery
voltage
Shows the current voltage of the battery for the real-time clock
in the main module.
Motor running
time
Shows the total operating time of the compressor motor in hours,
minutes and seconds.
Idling
Shows the share of time in which the compressor was idling in
hours, minutes and seconds.
Efficiency display
Shows the ratio of load energy compared to total operating time
energy since the preceding Reset.
Load cycles of internal
receiver
Counts the effected load cycles of the internal combination re-
ceiver.(One cycle consists of 1 x output and 1 x no output each).
Normally not used for piston compressors.