31
2. Installation
2.1 Wall installation - Sigle-sided clock
2.1.1 Mechanical installation
Where the clock is to be installed, drill three holes in the wall according to the following layout and
dimensions pertaining to your model:
A
D
C
B
750
760
A
410
B
170
C
170
D
340
325
135
135
270
For standard mounting on a concrete wall, insert the anchors into the drilled holes.
To install the clock on the wall, the clock must first be opened.
To do this:
- Loosen and remove the air inlet screw
1
located on the underside of the clock to let air in
(6mm Allen key),
Air inlet screw
Torque:
15 Nm
1
Movement
connector
2
Cover screws
Torque: 1.2 Nm
- Partially loosen the four cover screws
2
(two on each side)
located on the clock (3 mm Allen key),
- Gently slide forward and remove partially the clock face in
order to access the internal cabling,
- Disconnect the flat cable connected to the movement of the
clock face,
- Completely remove the clock face. You can now access
the interior of the clock and mount it on the wall,
- Place the clock face on a clear, clean and
flat work surface,
EN