Page 6
marked L and the white or neutral wire to terminal marked N on the connector block.
DEDICATED LINE IS REQUIRED FOR EACH 115-VOLT DRYER.
For Model B-740 208
–240V and B-748 208–240V Dryers:
Connect ground (earth) wire to
ground (earth) terminal on the mounting base marked
, the Live or Hot wire to the
terminal marked L (L1) and the Neutral wire to the terminal marked N on the connector
block.
Secure electrical wire in strain relief clamp provided on mounting base.
REPLACE COVER
Replace cover by positioning the top retaining bracket at top rear edge of cover, behind the
back of mounting base. Tilt cover downwards and over flange on air inlet/outlet grille.
Ensure that the rubber strip is in place between the cover and the grille.
NOTE
: Space between cover and wall must be the same on both sides.
Tighten the single cover-locking screw located in recess in the air inlet/outlet grille.
CHECK DRYER OPERATION
Turn electrical supply on. Position hands under air-outlet opening and dryer should turn on.
Remove hands from under air-outlet opening and dryer should stop.