Page 24
DEDICATED LINE IS REQUIRED FOR EACH 115 VOLT DRYER.
For 208
–240 Volt Dryers:
Connect ground (earthed) wire to ground (earthed) terminal
marked
and the 208-240 Volt wires to terminals marked L(L1) and N (L2).
Make sure excess wire does not interfere with operation of dryer.
REPLACE COVER.
Replace cover by positioning top of cover on studs on top of aluminum base unit and
tipping bottom of cover toward aluminum base. Push bottom of cover firmly against base.
NOTE:
Space between cover and base must be the same on bottom and both sides.
To tighten two cover bolts, insert Allen wrench into holes on bottom edge of cover. Make
sure wrench fits into head of cover bolts and turn COUNTERCLOCKWISE until bolts are
tightened.
NOTE:
Do not over tighten cover bolts; over tightening cover bolts may damage
enamel finish.
CHECK DRYER OPERATION.
To check operation of dryer, follow these instructions:
For Touch Button Hair Dryers:
Turn electrical power on. Touch the chrome-plated touch
button once and dryer should turn on. Touch the touch button again after a few seconds
and dryer should stop. If left on Hair Dryers will shut off after 80 seconds.
For Automatic Hand Dryers:
Turn electrical power supply on. Position hands under nozzle
and dryer should turn on. Remove hands from under nozzle and dryer should stop.
Summary of Contents for AirCraft B-701
Page 32: ...Page 26 Schematic Diagram 115V Dryer Schematic Diagram 208 240V Automatic Dryer ...
Page 33: ...Page 27 Schematic Diagram 208 240V Touch Dryer ...
Page 42: ...Page 9 ...
Page 50: ...Page 8 ...
Page 58: ...Page 8 Schematic Diagram 115V Dryer Schematic Diagram 208 240V Dryer ...
Page 66: ...Page 8 ...