Page 5
Hold the Installation Template against the wall in the desired location of the installed dryer,
see following recommended mounting heights.
Recommended Mounting Heights:
Distance from floor to bottom of mounting base.
Men's Washrooms ....................................................... 46-1/2'' (1185mm)
Women's Washroom ................................................... 44-1/2'' (1135mm)
Children's Washrooms, Age 3-9 .................................. 32-1/2'' (830mm)
Children's Washrooms, Age 9-12 ................................. 36-1/2'' (930mm)
Children's Washrooms, Age 12-15 ............................... 40-1/2'' (1030mm)
Children's Washrooms, Ages 15-18 ............................ 44-1/2'' (1135mm)
Barrier-Free Design ...................................................... 38-1/2'' (980mm)
Make sure line on template representing bottom of dryer mounting base is horizontal and
located at the desired height above floor.
Mark center of three mounting screw holes and hole for entry of electrical wiring if electrical
supply is concealed in wall and will enter dryer from back through mounting base.
NOTE
: Surface-mounted electrical supply entry is located in the lower right corner of the
mounting base. Bottom of mounting base has an opening in lower right corner to
accommodate connection of electrical conduit.
Drill three holes for #10 (M4.8) mounting bolts or screws (not furnished).
For masonry walls provide three #10 expansion shields or anchors and secure with three
#10 (M4.8) sheet-metal screws (not furnished). For plaster or dry wall construction, provide
concealed backing to comply with local building codes and secure with three #10 (M4.8)
round-head sheet-metal screws, or 3/16'' (5mm) toggle bolts (not furnished).
NOTE
: Use 1-1/4'' (35mm) long screws.
Fasten mounting base securely to wall.
ELECTRICAL CONNECTION
FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL BUILDING CODE. UNIT
MUST BE INSTALLED BY A QUALIFIED LICENSED ELECTRICIAN.
WARNING: TURN ELECTRICAL POWER SUPPLY OFF BEFORE MAKING
ELECTRICAL CONNECTIONS.
Connect dryer to nearest distribution panel. Use wire as required by local electrical code. In
the United States and Canada use #12 wire.
Wiring Instructions:
A fused means for disconnection in all poles must be provided in the fixed wiring in
accordance with the wiring rules.
Trim insulation from end of electrical wire.
Summary of Contents for AirCraft B-701
Page 32: ...Page 26 Schematic Diagram 115V Dryer Schematic Diagram 208 240V Automatic Dryer ...
Page 33: ...Page 27 Schematic Diagram 208 240V Touch Dryer ...
Page 42: ...Page 9 ...
Page 50: ...Page 8 ...
Page 58: ...Page 8 Schematic Diagram 115V Dryer Schematic Diagram 208 240V Dryer ...
Page 66: ...Page 8 ...