Boann Reverse Osmosis 5-Stage Water Filtration System User Manual Download Page 9

9

boannstyle.com

Using the EZ Angle Stop Adapter

The Boann R.O. 5-Stage Water Filtration System comes with the EZ Angle Stop Adapter (NSF 

Certified). The adapter is a convenient and user-friendly part that faciliates installation. PLEASE 

NOTE YOU DO NOT NEED TO TURN OFF THE MAIN WATER SUPPLY LINE when using the EZ 

Angle Stop Adapter. 

DO NOT use Teflon tape on this product. 

1. To start, turn both Hot and Cold water valves clockwise, turning Off water to both water lines. 

    Turn the sink faucet On to make sure no cold water is flowing. Next, use a wrench to unscrew  

    the cold water hose from the Cold Water Valve.

2. If the white gasket is not attached to the EZ Angle Stop Adapter, place and push the gasket into 

    the female threads. After, screw the EZ Angle Stop Adapter onto the 3/8” male threads on the 

    Cold Water Valve. When resistance is felt, tighten the EZ Angle Stop Adapter one full rotation, 

    securing the adapter.

Installation Preparation

Turn Valve 

Clockwise to 

Turn Off

Note!

The Mur-lock® Union-Tee Fitting (V0420426) can be purchased and used 

as a supplement fitting to connect a 1/4” refrigeration water line to the 

water filtration system.  

Summary of Contents for Reverse Osmosis 5-Stage Water Filtration System

Page 1: ......

Page 2: ......

Page 3: ...y premature system degradation After installation is complete and deemed successful please read the Recommended Filter Replacement Schedule section on page 19 and keep record on your calender when you...

Page 4: ...Adapter 9 The Auto Leak Detector Advantage 11 Re Activating the Auto Leak Detector 11 R O Filtration System Installation 12 Preparing the Discharge Water Drain Clamp 12 Prepare the R O Pressure Stora...

Page 5: ...ation process Parts Diagram 1 Parts Diagram 2 Parts Diagram 3 Package Contents Drain Clamp ACW 2 and Gasket Water Feed Connector AB 3 4 Auto Leak Detector Screws 5 Gal Pressure Storage Water Tank Fauc...

Page 6: ...LY Provided below are images showing the front and rear of the filtration system with filters intact We recommend to thoroughly read the installation instructions step by step in order to expeditiousl...

Page 7: ...Microfiltration Chlorine Odor Organic Chemicals Stage 3 Carbon Pre Filter Ultrafiltration Chlorine Bad taste Odor Stage 4 RO Membrane Filter Filters dissolved minerals salts and most harmful chemical...

Page 8: ...and determine the proper location for the unit and tank Please consider easy accessibility as it is required to periodically service the filtration system and its parts Tip Understanding installation...

Page 9: ...Turn the sink faucet On to make sure no cold water is flowing Next use a wrench to unscrew the cold water hose from the Cold Water Valve 2 If the white gasket is not attached to the EZ Angle Stop Adap...

Page 10: ...r end of the red PE Tubing to the R O System Out port on the Auto Leak Detector Next use the other cut red PE tubing and attach it to the Main Line In port on the Auto Leak Detector Installation Prepa...

Page 11: ...shut down due to a leak the replacement of the used cell will be required 2 To open the housing module simply pry the upper spring trigger with your hand or use a flat screwdriver to detach pry the up...

Page 12: ...ut the chosen spot with a 1 4 drill bit The 1 4 hole that is created into the chosen location on the drain pipe is where the black discharge line will be inserted and secured into place with the Disch...

Page 13: ...he Discharge Water Drain Clamp in its chosen location making sure the tubing is inserted into the drain pipe by 1 4 inch as shown 5 Assemble the two pieces of the Discharge Water Drain Clamp with use...

Page 14: ...ecurity apply 5 8 wraps of Teflon tape to the thread of the tank 2 The yellow PE tubing will now be used to connect the system to the R O Pressure Storage Water Tank Connect the yellow PE tubing into...

Page 15: ...2 hole in the sink or counter top or utilize an existing hole should it be the appropriate size 2 Slide chrome cover plate and rubber gasket onto stem of faucet and place the faucet onto the sink wit...

Page 16: ...ng hole should it be the appropriate size 2 Slide chrome cover plate and rubber gasket onto stem of faucet and place the faucet onto the sink with the stem going through the hole 3 Attach plastic loca...

Page 17: ...iculates and carbon dust IMPORTANT It is advisable to turn on the cold water tap on the kitchen faucet to make sure there are no leaks anywhere within the plumbing system It is important to allow the...

Page 18: ...Stage Water Filtration System please employ Teflon tape by way of wrapping the threads of the various threaded fittings 5 7 times This preventative measure will assist in preventing potential leaks f...

Page 19: ...O Membrane is rated for 4 000 5 000 Gallons of purified water production A new R O Membrane will last approximately 3 4 years However it is suggested replacing the R O Membrane every 2 years for syst...

Page 20: ...ent Filter Replacement Guide Step 1 Lift up filter approximately 30 degrees from R O filtration system Step 2 Twist filter counter clock wise and gently remove the filter from the filter housing Step...

Page 21: ...ard from the R O filtration system approximately 45 3 Grip the filter with one hand and proceed to unscrew the filter counter clockwise in a 1 3 rotation 4 At this point the filter should detach from...

Page 22: ...n 375 South 6th Avenue City of Industry CA 91746 Boann has the right at its discretion to replace or repair returned equipment Replaced equipment may be reconditioned Parts used in repairing or replac...

Page 23: ......

Page 24: ...Boann Specialized Stainless Steel Kitchen and Bath Hardware...

Reviews: