Use a
MAINTENANCE
■
Maintenance
Disconnect the machine from the power
supply before any maintenance.
■
Maintenance jobs
■
Cleaning the boiler
We recommend eliminating any scale
deposits from the boiler at least twice a year
as follows:
-
Disconnect the machine from the
power supply.
-
Place a container under the machine,
then remove the boiler cap , using round
nose pliers or the spanner provided
- Drain the boiler into the container, then
screw the boiler cap.
■
Cleaning the filters
Check that the Hepa filter, the activated
carbon filter and the filter of the motor air
inlet are clean. If necessary, replace these
filters using original spare parts.
In any case, we recommend replacing such
filters
yearly.
Replacing the Hepa filter :
-
Disconnect the machine from the power
supply.
-
Open the grille on the right side by pushing
the
relevant fixing.
- Replace filter
S
and refit the grille.
This job must be performed after the machine
has cooled down completely.
Replacing the activated carbon filter :
-
Open the grille on the left side by pushing
the
relevant fixing.
- Replace filter
T
and refit the grille.
CAUTION
T
S