EN14
CALIBRATION
To achieve a starting position for the degree of purification
based specifically on your water, the water purifier must be
calibrated (reset).
Calibration may only be performed if:
The water purifier is new and has never been used before.
The incoming water quality changes for some reason, such
as moving the water purifier.
Membrane replacement has recently been carried out.
Do not drink or use the water that is produced dur-
ing the calibration procedure!
To calibrate the water purifier:
a)
With tap installed:
Open the purified water tap. Within 10 seconds (with
the tap still open), you must press the calibration
button, see FIG. 14. Hold it depressed until the lights
for purification levels I and II come on and then go
out. When only the On/Off light is lit, the button can
be released.
b)
Without tap connected:
After the third automatic flushing in the flushing
procedure, which takes 30 seconds, the water purifier
stops for a second and then starts producing purified
water to the reject water outlet. Once the production
of purified water has started, the calibration button
must be pressed within 10 seconds, see
FIG. 14, and then kept depressed until the lights for
purification levels I and II come on and then go out.
When only the On/Off light is lit, the button can be
released.
If any of the lights for purification levels I-III does
not go out, go through the Checkpoints under
FLUSHING
again and restart calibration.
Allow the water purifier to produce purified water
for at least 10 minutes. The lights for purification
levels I and II flash once. The current water quality
level is displayed by the lamp for level III starting to
shine continuously, indicating the maximum degree
of purity.
If a wandering flashing light appears between the
lights for levels I - III, the calibration has been car-
ried out incorrectly. In this case, repeat the calibra-
tion from the beginning.
a)
With tap installed:
Close the purified water tap and allow the water puri-
fier to flush automatically. Allow the flushing to stop.
b)
Without tap installed:
Pull out the plug, wait for one minute and then
reconnect it. The water purifier flushes. Pull out the
plug after the automatic flushing. Connect the puri-
fied water hose to the peripheral equipment.
The water purifier is now ready to produce puri-
fied water.
•
•
•
1
2.
3.
4
INSTALLATION
MOVING THE WATER PURIFIER
If you move the purifier from one place to another, you should
remember the following points:
Close the shut-off valve for the feed water.
Pull out the plug.
Always transport the appliance upright.
Installation takes place according to the installation instruc-
tions.
New calibration should only be performed if the quality of
the feed water has changed, or if the membrane has been
replaced.
The appliance must be put in storage if it is not going to
be used for a period of more than 4 months, refer to