EN6
METHOD B
During the cleaning procedure, which takes approximately
30 minutes, you cannot use the water purifier.
Mix approximately 2.5 dl of descaling agent (equiva-
lent to 200 g) with 2 litres of lukewarm water in a
bucket. Stir until the powder has dissolved.
Pull out the plug. Remove both filter I and filter II
from the containers in accordance with
REPLAC-
ING THE FILTERS
and screw in the empty contain-
ers again. (Do not discard the filters. These can be
reused.)
If the purified water tap is not installed, ensure that
the purified water from the water purifier can be
flushed to the reject water outlet by disconnecting
the purified water hose from another product or pe-
ripheral equipment and leading it to the reject water
outlet via the gap.
Close the shut-off valve at the water connection.
Disconnect the feed water hose from the water con-
nection and the reject water hose from the reject
water outlet.
Insert the ends of the feed water and reject water
hoses into the bucket. Ensure that the ends remain
below the surface throughout the cleaning procedure.
Connect the plug and allow the water purifier to flush
automatically. Pull out the plug after approximately
30 seconds. (During flushing, the water purifier
draws in the mixture from the bucket. The volume in
the bucket reduces by the same volume that was in
the pre-filter containers, but consequently does not
disappear completely.)
Wait 1 minute. Repeat step 6 again.
Now allow the descaling agent to act for 2 minutes,
and then repeat step 6 again.
Wait for 2 minutes and then repeat step 6 once more.
Reconnect the feed water hose to the water con-
nection and the reject water hose to the reject water
outlet.
Connect the plug and allow the water purifier to per-
form a complete automatic flush. Then produce puri-
fied water to the reject water outlet for 30 seconds
before pulling out the plug.
Flush the water purifier according to section
FLUSH-
ING
. Reset the equipment and reconnect the purified
water hose to another product or peripheral equip-
ment.
Cleaning/Descaling is now completed. The water
purifier is ready to be used as normal.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
MAINTENANCE
CLEANING/DESCALING
When the flow is reduced (due to clogging), the water purifier
should be cleaned to extend its lifetime. When the flow cannot
be restored despite cleaning and filter replacement, contact your
dealer for possible membrane replacement.
Cleaning/Descaling the water purifier is performed:
When the flow from the water purifier has reduced
At least every 6 months
Descaling agents can be ordered from your dealer, see
CONSUM-
ABLES
.
The descaling agent must be kept out of the reach of
children! Wash your hands after cleaning.
Water containing descaling agent will be produced.
This water must not be drunk or routed into
peripheral equipment or another product.
There are 2 methods for cleaning/descaling the water purifier.
Method A takes 10 hours and method B takes 30 minutes.
METHOD A
During the cleaning procedure, which takes approximately
10 hours in total, you cannot use the water purifier.
If the purified water tap is not installed, a valve should be
installed on the purified water hose so that the water purifier
can be controlled via this. Also ensure that the purified water
from the water purifier can be flushed to the reject water outlet
by disconnecting the purified water hose from another product
or peripheral equipment and leading it to the reject water outlet
via the gap.
Pull out the plug and connect it again so that the
water purifier flushes.
Ensure that purified water production has stopped.
Keep the water purifier connected to the mains.
Unscrew filter container II, see
REPLACING THE
FILTERS
for instructions. Place the filter to one side.
RO600C/RO600CV
: Remove filter I and II from the
containers.
Add approximately 2.5 dl descaling agent (equiva-
lent to 200 g) in the filter container. Fill with luke-
warm water (20 – 40 °C) almost up to the edge. Stir
until the powder has dissolved.
Screw the filled container into place using the filter
spanner.
Open the purified water tap/valve and allow the
water purifier to flush water to the reject water outlet
for 45 seconds.
With the tap/valve still open, pull out the plug
.
Close the tap/valve and allow the water purifier to
stand for approximately 10 hours (e.g. overnight).
Remove the filter container after this resting period.
Pour away the content and rinse out with water.
Replace the filter in the container, see
REPLACING
THE FILTERS
for instructions, except that the previ-
ously used filter is used here.
Flush the water purifier, see
FLUSHING
for instruc-
tions.
Reset the equipment.
Cleaning/Descaling is now completed. The water
purifier is ready to be used as normal.
•
•
1.
2.
3.
4.