background image

WARNING –

This product should be installed and serviced only by a qualified professional.

Pump Location

Locate pump as close to pool as practical and run suction lines as direct as possible to reduce friction loss. Suction
lines should have continuous slope upward from lowest point in line. Joints must be tight (but not over-tightened).
Suction line diameter must equal or be larger than the discharge line diameter.
Though the pump is designed for outdoor use, it is strongly advised to protect the electrical components from the
weather. Select a well-drained area, one that will not flood when it rains.

Do NOT install pump in a damp or

non-ventilated location.

Keep motor clean. Pump motors require free circulation of air for cooling.

Pump Mounting

Install pump on a firm, level base or pad to meet all local and national codes. Fasten pump to base or pad with
screws or bolts to further reduce vibration and stress on pipe or hose joints. The base MUST be solid, level, rigid,
and vibration free.

Pump mount must:

 

Allow pump inlet height to be as close to water level as possible.

 

Allow use of short, direct suction pipe (to reduce friction losses).

 

Allow for gate valves in suction and discharge piping.

 

Be protected from excess moisture and flooding.

 

Allow adequate access for servicing pump and piping.

Pipe Sizing Chart

NOTE

- It is recommended that a minimum length of piping

MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE

Pipe Size

[mm]

1”

[32]

1 1/4”

[40]

Flow rate

GPM[Liter/Min]

20

[75]

30

[110]

Pipe Size

[mm]

1 1/2”

[50]

2”

[63]

Flow rate

GPM[Liter/Min]

45

[170]

80

[300]

Pipe Size

[mm]

2 1/2”

[75]

3”

[90]

Flow rate

GPM[Liter/Min]

110

[415]

160

[600]

, equivalent to 10 pipe diameters, be used between the

pump suction inlet and any plumbing fittings.

WARNING –

Hazardous Pressure.

Pumps, filters, and other equipment/ components of a swimming pool filtration system operate under pressure.
Incorrectly installed and/or improperly tested filtration equipment and/or components may fail resulting in injury
and/or property damage.

Plumbing

Use

T

“             ”

“             ”

eflon tape

t

available at any plumbing or hardware store, o seal threaded connections on molded plastic

components. All plastic fittings must be new or thoroughly cleaned before use.

NOTE - Do NOT use Plumber’s

Pipe Dope as it may cause cracking of the plastic components.

When applying Teflon tape to plastic threads,

wrap the entire threaded portion of the male fitting with one to two layers of tape. Wind the tape clockwise as you

face the open end of the fitting, beginning at the end of the fitting. The pump suction and outlet ports have
molded-in thread stops.

Do NOT attempt to force

page 5

Installation Instructions

,

hose connector fitting past this stop.

It is only necessary to

Summary of Contents for Flow Xtreme NE4513

Page 1: ...REPLACEMENT PUMPS OWNER S MANUAL INSTALLATION OPERATION PARTS NE4513 NE4515 NEP4208 NE4514 NE4516 NE4517 NE4520 NE4518 NE4521 NE4519 NE4522 NE4523 NEP4268 NEP4269 VER 0611 NE4524 NEP4271...

Page 2: ...so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for outdoor use it is strongly advised to protect the electri...

Page 3: ...tion outlets and or suction outlet covers which are damaged broken cracked missing or unsecured can cause severe injury and or death due to the following entrapment hazards Hair Entrapment Hair can be...

Page 4: ...nd water is discharged All suction and discharge valves MUST be OPEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage WARNING Separat...

Page 5: ...Allow adequate access for servicing pump and piping Pipe Sizing Chart NOTE It is recommended that a minimum length of piping MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE Pipe Size mm 1 32 1 1 4 4...

Page 6: ...electrical shock hazard WARNING Do NOT ground to a gas supply line WARNING To avoid dangerous or fatal electrical shock turn OFF power to motor before working on electrical connections WARNING Ground...

Page 7: ...5 ft 1 5 m of inside walls of swimming pool spa or hot tub Wiring WARNING All wiring must be done by a licensed electrician Pump MUST be permanently connected to circuit If other lights or appliances...

Page 8: ...t in severe personal injury Release all pressure from filter pump and piping system See filter owner s manual If water source is higher than the pump pump will prime itself when suction and outlet val...

Page 9: ...in the system Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time see instructions below Keep motor dry and covered during storage To avoid...

Page 10: ...r power drop frequently caused by undersized wiring or extension cord use Solution Contact qualified professional to check that the wiring gauge is heavy enough NOTE Your pump motor is equipped with a...

Page 11: ...seal only if it is leaking Low Flow Generally Check For 1 Clogged or restricted strainer or suction line Solution Contact a qualified repair professional 2 Undersized pool piping Solution Correct pip...

Page 12: ...tz Amps Flow Rate NE4517 HTI100 1 0 115 230 60 13 6 5 86GPM NE4518 HTI150 1 5 115 230 60 15 7 5 90GPM NE4519 HTI2SP075 0 75 0 23 230 60 6 80 35GPM NE4520 HTI2SP100 1 0 0 3 230 60 1 6 1 8 86 38GPM NE45...

Page 13: ...19 8 IMPELLER OF ITEM HTI 100 HTI2SP 100 HTI010 NEP4218 NE4517 NE4520 8 IMPELLER OF ITEM HTI 150 HTI2SP 150 HTI011 NEP4219 NE4518 NE4521 8 IMPELLER OF ITEM HTI 200 HTI2SP 200 HTI012 NEP4220 NE4522 9 O...

Page 14: ...4 All 9 PUMP COVER HTA011 NEP4195 All 10 O RING HTA012 NEP4196 All 11 IMPELLER OF ITEM HTA 075 HTA2SP 075 HTA014 NEP4198 NE4513 NE4515 IMPELLER OF ITEM HTA 100 HTA2SP 100 HTA015 NEP4199 NE4514 NE4516...

Page 15: ...5 43 O ring B 3 1 P00183 NEP4266 All 6 44 O ring C 1 5 1 P00184 NEP4267 All 7 45 Strainer Collar 1 P00133 NEP4247 All 8 46 Strainer Basket 1 P00134 NEP4248 All 9 47 Pump Drain Cap 1 P00135 NEP4249 All...

Reviews: