background image

Locate cord to prevent abuse from lawn mowers, hedge trimmers and other equipment.

WARNING

Connect only to a grounding type receptacle protected by a Ground Fault Circuit Interrupter

(GFCI).
Contact a licensed electrician if you cannot verify that the receptacle is protected by a GFCI.

WARNING

Failure to bond pump to pool structure will increase risk for electrocution and could result

in injury or death. To reduce the risk of electric shock, see installation instructions and consult a professional
electrician on how to bond pump.
Also, contact a licensed electrician for information on local electrical codes for bonding requirements.
Use a solid copper conductor, size 8 or larger. Run a continuous wire from external bonding lug to reinforcing rod
or mesh. Connect a No. 8 AWG (8.4 mm

2

) solid copper bonding wire to the pressure wire connector provided on

the motor housing and to all metal parts of swimming pool, spa, or hot tub, and to all electrical equipment, metal
piping (except gas piping), and conduit within 5 ft. (1.5m) of inside walls of swimming pool, spa, or hot tub.

IMPORTANT

- Reference NEC codes for all wiring standards including, but not limited to, grounding, bonding

and other general wiring procedures.

NOTE -

The National Electrical Code (NEC) permits use of a cord with a

maximum 3 ft. (1 m) length. If your pump is equipped with a cord complying with the NEC, the preceding four (4)
hazards apply.

WARNING

Suction Entrapment Hazard.

Entrapment in suction outlets and/or suction outlet covers, which are damaged, broken, cracked, missing, or
unsecured can cause severe injury and/or death due to the following entrapment hazards:

Hair Entrapment

- Hair can become entangled in suction outlet cover.

Limb Entrapment

- A limb inserted into an opening of a suction outlet sump or suction outlet cover that is

damaged, broken, cracked, missing, or not securely attached can result in a limb becoming entrapped.

Body Suction Entrapment

- A pressure applied to a large portion of the body or limbs can result in an entrapment.

Mechanical Entrapment

- There is potential for jewelry, swimsuits, hair decorations, fingers, toes, or knuckles to

be caught in an opening of a suction outlet cover resulting in mechanical entrapment.

WARNING

To Reduce the risk of Entrapment Hazards:

- When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per
pump must be installed. Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three
feet (3’) [0.91 meter] apart, as measured from near point to near point.
- Dual suction fittings shall be placed in such locations and distances to avoid “dual blockage” by a user.
- Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas.

- The maximum system flow rate shall not exceed the values shown in the “Pipe Sizing Chart” found at the bottom

of page 5 of this manual.

- Never use pool or spa if any suction outlet component is damaged, broken, cracked, missing, or not securely
attached.
- Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately.

page 3

Summary of Contents for Flow Xtreme NE4513

Page 1: ...REPLACEMENT PUMPS OWNER S MANUAL INSTALLATION OPERATION PARTS NE4513 NE4515 NEP4208 NE4514 NE4516 NE4517 NE4520 NE4518 NE4521 NE4519 NE4522 NE4523 NEP4268 NEP4269 VER 0611 NE4524 NEP4271...

Page 2: ...so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for outdoor use it is strongly advised to protect the electri...

Page 3: ...tion outlets and or suction outlet covers which are damaged broken cracked missing or unsecured can cause severe injury and or death due to the following entrapment hazards Hair Entrapment Hair can be...

Page 4: ...nd water is discharged All suction and discharge valves MUST be OPEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage WARNING Separat...

Page 5: ...Allow adequate access for servicing pump and piping Pipe Sizing Chart NOTE It is recommended that a minimum length of piping MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE Pipe Size mm 1 32 1 1 4 4...

Page 6: ...electrical shock hazard WARNING Do NOT ground to a gas supply line WARNING To avoid dangerous or fatal electrical shock turn OFF power to motor before working on electrical connections WARNING Ground...

Page 7: ...5 ft 1 5 m of inside walls of swimming pool spa or hot tub Wiring WARNING All wiring must be done by a licensed electrician Pump MUST be permanently connected to circuit If other lights or appliances...

Page 8: ...t in severe personal injury Release all pressure from filter pump and piping system See filter owner s manual If water source is higher than the pump pump will prime itself when suction and outlet val...

Page 9: ...in the system Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time see instructions below Keep motor dry and covered during storage To avoid...

Page 10: ...r power drop frequently caused by undersized wiring or extension cord use Solution Contact qualified professional to check that the wiring gauge is heavy enough NOTE Your pump motor is equipped with a...

Page 11: ...seal only if it is leaking Low Flow Generally Check For 1 Clogged or restricted strainer or suction line Solution Contact a qualified repair professional 2 Undersized pool piping Solution Correct pip...

Page 12: ...tz Amps Flow Rate NE4517 HTI100 1 0 115 230 60 13 6 5 86GPM NE4518 HTI150 1 5 115 230 60 15 7 5 90GPM NE4519 HTI2SP075 0 75 0 23 230 60 6 80 35GPM NE4520 HTI2SP100 1 0 0 3 230 60 1 6 1 8 86 38GPM NE45...

Page 13: ...19 8 IMPELLER OF ITEM HTI 100 HTI2SP 100 HTI010 NEP4218 NE4517 NE4520 8 IMPELLER OF ITEM HTI 150 HTI2SP 150 HTI011 NEP4219 NE4518 NE4521 8 IMPELLER OF ITEM HTI 200 HTI2SP 200 HTI012 NEP4220 NE4522 9 O...

Page 14: ...4 All 9 PUMP COVER HTA011 NEP4195 All 10 O RING HTA012 NEP4196 All 11 IMPELLER OF ITEM HTA 075 HTA2SP 075 HTA014 NEP4198 NE4513 NE4515 IMPELLER OF ITEM HTA 100 HTA2SP 100 HTA015 NEP4199 NE4514 NE4516...

Page 15: ...5 43 O ring B 3 1 P00183 NEP4266 All 6 44 O ring C 1 5 1 P00184 NEP4267 All 7 45 Strainer Collar 1 P00133 NEP4247 All 8 46 Strainer Basket 1 P00134 NEP4248 All 9 47 Pump Drain Cap 1 P00135 NEP4249 All...