background image

- In addition to two or more suction outlets per pump installed in accordance with latest IAF (formerly NSPI)
standards and CPSC guidelines, follow all national, state, and local codes applicable.
- Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended.

WARNING

Hazardous Pressure.

Pool and spa water circulation systems operate under hazardous pressure during start-up, normal operation, and
after pump shut-off. Stand clear of circulation system equipment during pump start-up. Failure to follow safety and
operation instructions could result in violent separation of the pump housing and cover due to pressure in the
system, which could cause property damage, severe personal injury, or death. Before servicing pool and spa water
circulation system, all system and pump controls must be in off position and filter manual air relief valve if part of
the filtration system must be in open position. Before starting system pump, all system valves must be set in a
position to allow system water to return back to the pool. Do not change filter control valve position while system
pump is running. Before starting system pump, fully open filter manual air relief valve. Do not close filter manual
air relief valve until a steady stream of water (not air or air and water) is discharged. All suction and discharge
valves

MUST

be

OPEN

when starting the circulation system.

Failure to do so could result in severe personal injury and/or property damage.

WARNING

Separation Hazard.

Failure to follow safety and operation instructions could result in violent separation of pump components. Strainer
cover must be properly secured to pump housing with strainer cover lock ring. Before servicing pool and spa
circulation system, all system and pump controls must be in off position and filter manual air relief valve must be
in open position. Do not operate pool and spa circulation system if a system component is not assembled properly,
damaged, or missing. Do not operate pool and spa circulation system unless filter air relief valve body is in closed
position. All suction and discharge valves

MUST

be

OPEN

when starting the circulation system.

Failure to do so could result in severe personal injury and/or property damage.

WARNING

Never operate or test the circulation system at more than 40 PSI.

WARNING

Fire and burn hazard.

Motors operate at high temperatures and if they are not properly isolated from any flammable structures or foreign
debris they can cause fires, which may cause severe personal injury or death. It is also necessary
to allow the motor to cool for at least 20 minutes prior to maintenance to minimize the risk for burns.

WARNING

Failure to install according to defined instructions may result in severe personal injury or

death.

page 4

Summary of Contents for Flow Xtreme NE4513

Page 1: ...REPLACEMENT PUMPS OWNER S MANUAL INSTALLATION OPERATION PARTS NE4513 NE4515 NEP4208 NE4514 NE4516 NE4517 NE4520 NE4518 NE4521 NE4519 NE4522 NE4523 NEP4268 NEP4269 VER 0611 NE4524 NEP4271...

Page 2: ...so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for outdoor use it is strongly advised to protect the electri...

Page 3: ...tion outlets and or suction outlet covers which are damaged broken cracked missing or unsecured can cause severe injury and or death due to the following entrapment hazards Hair Entrapment Hair can be...

Page 4: ...nd water is discharged All suction and discharge valves MUST be OPEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage WARNING Separat...

Page 5: ...Allow adequate access for servicing pump and piping Pipe Sizing Chart NOTE It is recommended that a minimum length of piping MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE Pipe Size mm 1 32 1 1 4 4...

Page 6: ...electrical shock hazard WARNING Do NOT ground to a gas supply line WARNING To avoid dangerous or fatal electrical shock turn OFF power to motor before working on electrical connections WARNING Ground...

Page 7: ...5 ft 1 5 m of inside walls of swimming pool spa or hot tub Wiring WARNING All wiring must be done by a licensed electrician Pump MUST be permanently connected to circuit If other lights or appliances...

Page 8: ...t in severe personal injury Release all pressure from filter pump and piping system See filter owner s manual If water source is higher than the pump pump will prime itself when suction and outlet val...

Page 9: ...in the system Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time see instructions below Keep motor dry and covered during storage To avoid...

Page 10: ...r power drop frequently caused by undersized wiring or extension cord use Solution Contact qualified professional to check that the wiring gauge is heavy enough NOTE Your pump motor is equipped with a...

Page 11: ...seal only if it is leaking Low Flow Generally Check For 1 Clogged or restricted strainer or suction line Solution Contact a qualified repair professional 2 Undersized pool piping Solution Correct pip...

Page 12: ...tz Amps Flow Rate NE4517 HTI100 1 0 115 230 60 13 6 5 86GPM NE4518 HTI150 1 5 115 230 60 15 7 5 90GPM NE4519 HTI2SP075 0 75 0 23 230 60 6 80 35GPM NE4520 HTI2SP100 1 0 0 3 230 60 1 6 1 8 86 38GPM NE45...

Page 13: ...19 8 IMPELLER OF ITEM HTI 100 HTI2SP 100 HTI010 NEP4218 NE4517 NE4520 8 IMPELLER OF ITEM HTI 150 HTI2SP 150 HTI011 NEP4219 NE4518 NE4521 8 IMPELLER OF ITEM HTI 200 HTI2SP 200 HTI012 NEP4220 NE4522 9 O...

Page 14: ...4 All 9 PUMP COVER HTA011 NEP4195 All 10 O RING HTA012 NEP4196 All 11 IMPELLER OF ITEM HTA 075 HTA2SP 075 HTA014 NEP4198 NE4513 NE4515 IMPELLER OF ITEM HTA 100 HTA2SP 100 HTA015 NEP4199 NE4514 NE4516...

Page 15: ...5 43 O ring B 3 1 P00183 NEP4266 All 6 44 O ring C 1 5 1 P00184 NEP4267 All 7 45 Strainer Collar 1 P00133 NEP4247 All 8 46 Strainer Basket 1 P00134 NEP4248 All 9 47 Pump Drain Cap 1 P00135 NEP4249 All...

Reviews: