29
ENGLISH
DISPLAYED ALARMS and WARNINGS: SELF-DIAGNOSTICS
A1
CYCLE NOT COMPLETED
This alarm is displayed when the wash cycle
was interrupted by switching the machine off
with the START key.
The alarm is reset when the next wash cycle starts
A2
ANOMALOUS OVERHEATING (BOILER)
This alarm is displayed when the temperature in
the boiler
exceeds 105 °C
or when at least one of the temperature probes
(tank/boiler) is short-circuited.
The alarm is reset when the temperature
drops
below 102°C
or when the probe is
replaced.
A 3
TEMPERATURE PROBE DISCONNECTED
This alarm is displayed when one of the
temperature probes (boiler and/or tank) is
disconnected or interrupted.
The alarm is reset when the probe is
reconnected properly.
A 4
FILLING TIMEOUT (RCD versions)
This alarm is displayed when the tank does not fill
within 30 minutes
or the boiler does not
fill
within 6 minutes
The alarm can be reset by pressing the START key.
A 5
BOILER HEATING TIMEOUT
This alarm is displayed if the boiler is not heated
within 30 minutes.
The alarm can be reset by pressing the START key
A6
WATER DRAINING TIMEOUT (partial dumper)
This alarm is displayed if the drain cycle does not
finish
within 4 minutes
.
The alarm can be reset by pressing the START key.
H 1
INSUFFICIENT RINSE WATER TEMPERATURE.
This alarm is displayed if, during the wash cycle,
the rinse phase is carried out with the boiler
at least
15°C lower
than the set temperature.
The washing cycle is prolonged until the maximum
rinsing temperature is reached (max 8 minutes)
H2
WATER MISSING
This alarm is displayed when water is detected
to be missing.
The alarm can be reset by pressing the START key
ATTENTION
If more than one alarm is triggered simultaneously,
the display will show the relative codes based on this
order of priority:
1. H1-H2-H3
2. A1-A2-A3-A4-A5
3. F1-F2-F3
The alarm and warning codes of the active functions
displayed during machine operation are:
The START key turns RED until
normal conditions are restored
If an ALARM or WARNING condition occurs, the relative
code will be displayed.
H3
INSUFFICIENT WASH WATER TEMPERATURE
This alarm is displayed if, during the cycle, the wash
phase is carried out
at least 10°C lower
than
the set temperature
F1
DOOR OPEN WARNING
This warning is displayed when the door is open.
It remains displayed until the door is closed
F2
INITIAL WATER FILLING
This warning is displayed when the machine is filling
water (only during regulation) (only with starting
temperature management active).
Part 3: Reserved for technician
Summary of Contents for SD 5 EC BT2
Page 1: ...Ed 03 2017 Instructions for use and maintenance SG SD 1 2 3 4 ...
Page 2: ......
Page 3: ......
Page 4: ...This page intentionally left blank ...
Page 9: ...7 Left space white intentionally ...
Page 13: ...11 Left space white intentionally ...
Page 29: ...27 PART RESERVED FOR AUTHORISED AND QUALIFIED TECHNICIAN ENGLISH ...
Page 33: ...31 Left space white intentionally ...
Page 35: ...33 Fig 9 Fig 8 12 13 11 10 14 15 16 17 21 19 18 1 2 3 4 ...
Page 36: ...ELECTRICAL DIAGRAM ...
Page 37: ......
Page 38: ......
Page 39: ......
Page 49: ......
Page 50: ......
Page 51: ...Left space white intentionally ...
Page 52: ...38 900891 ...