Installation
6
Clearances
NOTE: Only non-combustible materials can be used in close proximity to this appliance.
* Side clearances can be 50mm when adjacent surface is at least 100mm below cooking surface.
Assembly
NOTE:
Legs, pot stands, trivets and splashback are to be assembled during installation.
This appliance is fitted with adjustable feet to enable appliance to be positioned securely and level.
This should be carried out on completion of gas connection. Refer to ‘Gas Connection’ section.
Optional Accessories (Refer to Replacement Parts List)
1.
Check all feet are securely fitted.
2.
Adjust feet to make Range steady and level.
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN AUTHORISED PERSON.
1.
Blue Seal Ranges do not require an electrical connection, as they function totally on the gas supply only.
2.
It is essential that gas supply is correct for appliance being installed and that adequate supply pressure and
volume are available. The following checks should be made before installation:-
a. Gas Type the appliance has been supplied for, is shown on
coloured stickers located above gas connection point and on
rating plate. Check this is correct for gas supply appliance is
being installed for. Gas conversion procedure is shown in this
manual.
b. Supply Pressure required for this appliance is shown in
‘Specifications’ section of this manual. Check gas supply to
ensure adequate supply pressure exists.
c. Input Rate of this appliance is stated on Rating Plate and in
‘Specifications’ section of this manual. Input rate should be
checked against available gas supply line capacity. Particular
note should be taken if appliance is being added to an
existing installation.
NOTE: It is important that adequately sized piping runs directly to connection joint on appliance with as few
tees and elbows as possible to give maximum supply volume.
3.
For NAT Gas Only - Fit gas regulator supplied, into gas supply line as close to appliance as possible.
4.
For Propane Only - Directly connect the gas supply line to the appliance.
Fig 1
Rating Plate is located under bottom sill.
This appliance is for professional use and is only to be used by qualified
persons.
Only authorised service persons are to carry out installation, servicing or gas
conversion operations.
Caution
Combustible Surface
Non Combustible Surface
Left / Right hand side
150mm (*)
0mm
Rear 100mm 0mm
Summary of Contents for G750-6
Page 6: ...Dimensions 4 G750 6 ...
Page 20: ......