background image

Introduction

 

We are confident that you will be delighted with your BLUE SEAL GAS RANGE STATIC OVEN and it will  
become a most valued appliance in your commercial kitchen. 
 
To ensure you receive the utmost benefit from your new Blue Seal appliance, there are two important things you can 
do. 

 

Firstly: 

Please read the instruction book carefully and follow directions given.  The time taken will be well spent. 
 

Secondly: 

If you are unsure of any aspect of installation, instructions or performance of your appliance, contact your BLUE 
SEAL dealer promptly.  In many cases a phone call could answer your question. 

 
CE Only: 

These instructions are only valid if the country code appears on the appliance.  If code does not appear on appli-
ance, refer to supplier of this appliance to obtain technical instructions for adapting appliance to conditions for use 
in that country. 

 
 
 

G

REAT

 

CARE

 

MUST

 

BE

 

TAKEN

 

BY

 

THE

 

OPERATOR

 

TO

 

USE

 

THE

 

EQUIPMENT

 

SAFELY

 

TO

 

GUARD

 

IT

 

AGAINST

 

RISK

 

OF

 

FIRE



T

HE

 

APPLIANCE

 

MUST

 NOT 

BE

 

LEFT

 

ON

 

UNATTENDED



I

T

 

IS

 

RECOMMENDED

 

THAT

 

A

 

REGULAR

 

INSPECTION

 

IS

 

MADE

 

BY

 

A

 

COMPETENT

 

SERVICE

 

PERSON

 

TO

 

ENSURE

 

CORRECT

 

AND

 

SAFE

 

OPERATION

 

OF

 

YOUR

 

APPLIANCE

 

IS

 

MAINTAINED



DO NOT 

STORE

 

OR

 

USE

 

GASOLINE

 

OR

 

OTHER

 

FLAMMABLE

 

VAPOURS

 

OR

 

LIQUIDS

 

IN

 

THE

 

VICINITY

 

OF

 

THIS

 

OR

 

ANY

 

OTHER

 

APPLIANCE



DO

 

NOT

 

SPRAY

 

AEROSOLS

 

IN

 

THE

 

VICINITY

 

OF

 

THIS

 

APPLIANCE

 

WHILE

 

IT

 

IS

 

IN

 

OPERATION

Warning 

 
 
 



This appliance is for professional use and is only to be used by qualified 
persons. 



Only authorised service persons are to carry out installation, servicing or gas 
conversion operations. 



Components having adjustments protected (e.g. paint sealed) by the 

 

manufacturer should not be adjusted by the user / operator. 



DO NOT operate the appliance without the legs supplied fitted. 

Caution 

 
 

I

MPROPER

 

INSTALLATION

ADJUSTMENT

ALTERATION

SERVICE

 

OR

 

MAINTENANCE

 

CAN

 

CAUSE

 

PROPERTY

  

DAMAGE

INJURY

 

OR

 

DEATH

.  R

EAD

 

THE

 

INSTALLATION

OPERATING

 

AND

 

MAINTENANCE

 

INSTRUCTIONS

  

THOROUGHLY

 

BEFORE

 

INSTALLING

 

OR

 

SERVICING

 

THIS

 

APPLIANCE

Warning 

 
 
 
INSTRUCTIONS

 

TO

 

BE

 

FOLLOWED

 

IN

 

THE

 

EVENT

 

THE

 

USER

 

SMELLS

 

GAS

 

ARE

 

TO

 

BE

 

POSTED

 

IN

 

A

 

PROMINENT

 

LOCATION

.  

THIS

 

INFORMATION

 

SHALL

 

BE

 

OBTAINED

 

BY

 

CONSULTING

 

THE

 

LOCAL

 

GAS

 

SUPPLIER

Warning 

Summary of Contents for G750-6

Page 1: ...237494 1 I N S T A L L A T I O N A N D O P E R A T I O N M A N U A L For use in GB IE GAS RANGE STATIC OVEN G750 6 ...

Page 2: ...pares tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales ...

Page 3: ... 5 Installation Requirements Unpacking Location Clearances Assembly Gas Connection Commissioning Operation 8 Operation Guide Description of Controls Open Burners Oven Cleaning and Maintenance 10 Before Commencing Cleaning Stainless Steel Surfaces Vitreous Enamel Surfaces Open Burner Cleaning Oven Interior Cleaning Fault Finding 12 Gas Conversion and Specifications 13 Conversion Procedure Gas Speci...

Page 4: ...T NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION Warning This appliance is ...

Page 5: ...2H3P 20 37 Flue Type A1 Measure burner operating pressure at manifold test point with four burners operating at full setting Gas Connection Gas supply connection point is located at rear of appliance approximately 350mm from right hand side at rear of range and 742mm from floor and is reached from behind the appliance Refer to Dimensions section Connection is BSP male thread Natural Gas G20 Propan...

Page 6: ...Dimensions 4 G750 6 ...

Page 7: ...and transit protection from appliance including all protective plastic coating from exterior stainless steel panels Check equipment and supplied parts for damage Report any damage immediately to carrier and distributor Check that the following Parts have been supplied with your range 4 x Leg Adsjustable Report any deficiencies to distributor who supplied the appliance Securely fit the 4 legs suppl...

Page 8: ...d stickers located above gas connection point and on rating plate Check this is correct for gas supply appliance is being installed for Gas conversion procedure is shown in this manual b Supply Pressure required for this appliance is shown in Specifications section of this manual Check gas supply to ensure adequate supply pressure exists c Input Rate of this appliance is stated on Rating Plate and...

Page 9: ...tions section NOTE Operating pressure is to be measured at manifold test point and with 4 burners operating at High Flame setting 8 Verify operating pressure remains correct Commissioning 1 Before leaving new installation a Check following functions in accordance with operating instructions specified in Operation section of this manual Lighting the Open Burners Light the Oven Main Burner Check the...

Page 10: ...r Thermostat Oven Shut Down Description of Controls Gas Control Knobs Piezo Igniter Oven Oven Option OFF Position Temperature Graduations 130 C to 270 C Fig 3 Open Burner Option OFF Position HIGH Flame LOW Flame Rear Burner Front Burner Indicators are located above Gas Control Knobs This appliance is for professional use and is only to be used by qualified persons Only authorised service persons a...

Page 11: ...ntrol knob between HIGH and LOW positions Turning OFF the Open Burners 1 When main burner is not required turn gas control knob clockwise back to the OFF position burner will extinguish Oven Lighting the Oven Burner 1 Ensure the mains gas supply is turned On 2 Open Oven doors 3 Rotate thermostat control knob to the maximum temperature marked on the knob and hold knob depressed 4 Press the Piezo Ig...

Page 12: ...e Cooktop Ensure that any detergent or cleaning material has been completely removed after each cleaning To keep your Appliance clean and operating at peak efficiency follow the procedures shown overleaf Always turn off the gas supply to the appliance before commencing cleaning This appliance is not water proof Do not use water jet spray to clean interior or exterior of this appliance Caution ...

Page 13: ... Dry and polish all surfaces with a soft dry cloth Vitreous Enamel Surfaces NOTE Only use recommended cleaning products 1 Wipe vitreous enamel surfaces daily after use with a soft cloth and hot soapy water whilst the surfaces are still warm 2 Baked on deposits can be removed by soaking in hot soapy water with an approved detergent and cleaning with a moistened nylon or scotch cleaning pad 3 Dry an...

Page 14: ... Remove and clean injector Call service provider Faulty gas control Replace gas control Call service provider Main burner will not stay alight Faulty thermocouple connection Check thermocouple connection Call service provider Thermocouple incorrectly located Re position thermocouple Call service provider Main burner goes out when turned to Low position Blockage in gas valve Clean and re grease the...

Page 15: ...rrect size injectors as shown in Gas Specifications Tables at end of this section Refit the spill tray Refit the burner bases and burner heads Light main burners and check flame size on simmer LOW position 2 To Replace the low fire screw in the gas valves Remove the control panel Remove low fire screw from gas valves and replace with the correct size low fire screw as shown in Gas Specifications T...

Page 16: ...ctor holder and injector to the rear of the main burner Re connect gas supply tube to the main burner Refit the spark electrode to the mounting bracket was removed for access 4 To Replace the low fire screw in the gas valve Remove the control panel Remove low fire screw from gas valve and replace with correct size low fire screw as shown in Gas Specifications Tables at end of this section Low fire...

Page 17: ...s conversion replace gas type identification label located at Rear of appliance above gas connection Commissioning Before leaving the installation 1 Check all gas connections for leakage using soapy water or other gas detecting equipment 2 Carry out a Commissioning check of appliance as shown in Installation Section of this manual 3 Ensure any adjustments done to components that have adjustments s...

Page 18: ...his manual Part No Description Cook Top 237528 BURNER HEAD 237529 BURNER BASE 237530 JET HOLDER 237516 THERMOCOUPLE 237598 INJECTOR Propane Ø 1 20mm 237599 INJECTOR Nat Gas Ø 1 93mm 237526 GAS VALVE 237813 LOW FIRE SCREW Propane 51 237814 LOW FIRE SCREW Nat Gas 76 237534 KNOB OPEN BURNER Oven 237697 OVEN BURNER 237990 OVEN THERMOCOUPLE 238006 INJECTOR HOLDER 238004 OVEN BURNER INJECTOR Propane Ø 1...

Page 19: ... and Specifications 17 Gas Regulators Gas Conversion Kits Models Gas Type to Convert to Nat Gas UK Propane UK G750 6 238010 238009 Gas Type Gas Regulators Part No Description Nat Gas 238144 Regulator BSP RV48LM 6 Nat ...

Page 20: ......

Reviews: