Summary of Contents for 10310001

Page 1: ...User Manual Version 1 0 1 10310001 10310002 Hephaestus V094 V213 Vacuum Ovens User Manual ...

Page 2: ...3 VI Inspection 14 6 1 Packing List 14 VII Operating Instructions 15 7 1 Temperature Controller Panel 15 7 2 Functions 16 7 3 Priming the Vacuum Pump 17 7 4 Priming the Vacuum Oven 17 7 5 Setting of Temperature 17 7 6 Start Stop Operation 17 7 7 Setting the Deviation Alarm and Timer 18 7 8 Setting the Pre set Start Function 19 7 9 Setting the ENGINEER SETUP 19 7 10 Unit SYSTM Timer and PASSWORD Se...

Page 3: ... the Buyer to use the Products purchased in compliance with the applicable manufacturer s Published User Statement Limited User Statement or Limited License if any While this manual contains certain representations of the potential dangers from the instrument or equipment Buyer is solely responsible for conducting any research necessary to learn the hazards involved for any of its intended uses of...

Page 4: ... have from the original manufacturer or third party supplier to the extent such assignment is allowed by such original manufacturer or third party supplier In no event shall the Company have any obligation to make repairs replacements or corrections required in whole or in part as the result of i normal wear and tear ii accident disaster or event of force majeure iii misuse fault or negligence of ...

Page 5: ... ALL OTHER WARRANTIES EXPRESS OR IMPLIED ALL OTHER WARRANTIES ARE EXPRESSLY DISCLAIMED INCLUDING WITHOUT LIMITATION THOSE OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A SPECIFIC PURPOSE OR USE WHETHER ARISING FROM STATUTE OR OTHERWISE IN LAW OR FROM A COURSE OF DEALING OR USAGE OF TRADE THIS WARRANTY IS NOT TRANSFERABLE FROM THE ORIGINAL PURCHASER TO A SUBSEQUENT OWNER FURTHER THE COMPANY IS...

Page 6: ...TOTAL PURCHASE PRICE THERETOFORE PAID BY BUYER TO THE COMPANY WITH RESPECT TO THE PRODUCT S GIVING RISE TO SUCH LIABILITY OR B ONE HUNDRED THOUSAND DOLLARS 100 000 WHICHEVER IS LESS With respect to any software products incorporated in or forming a part of the Product hereunder Buyer intends and agrees that such software products are being licensed and not sold and that the words purchase sell or ...

Page 7: ...ve substances 8 The instrument is deenergised only when the power cable is disconnected from the power source 9 This instrument is for indoor use only 10 The instrument should be operated in a low humidity well ventilated dust and water free environment without direct sunshine or an intense magnetic light or heat source 11 Ensure that the instrument and its accessories are free of any potential de...

Page 8: ...d professional repair technicians can open the instrument or conduct required repairs Persons performing repairs on the instrument other than those selected or approved by the Company shall operate to void any warranty contained hereinabove for the product 19 The 304 stainless steel liner is not acid resistant please adhere to advised anti corrosion measures and NEVER use acidic media within the o...

Page 9: ...uum Oven is constructed from 304 stainless steel and the exterior surface of the oven is polymer coated The inner chamber uses either a galvanized or a stainless steel armour plate Fiberglass insulation is used to thermally insulate the chamber The cabinet door has a viewing window that allows visual inspection of the process The window is constructed using a double layered fortified glass design ...

Page 10: ...Vacuum Oven Overview The Hephaestus V094 V213 vacuum oven uses 5 15P power plug see figure below 1 2 3 4 5 1 vac gauge 2 controller 3 LED switch 4 vac valve 5 handle 6 LED 7 inlet 8 outlet kf25 9 power switch 10 power cord 11 gas air ...

Page 11: ...Upon contact the following information is required to be provided Product serial number located on rear panel instrument nameplate Warranty card Description of issue or problem i e software or hardware Method and or operating steps you have undertaken towards resolution Your contact details inclusive of telephone number and email address For claims under the warranty please contact your local supp...

Page 12: ...Material 304 Stainless Steel Inner Chamber Size mm 450 450 450 600 600 600 Oven Outer Dimensions mm 740 610 591 890 760 741 Note 1 This product is produced according to Q TIWY7 2004 2 All Technical specifications indexed are conducted under the situation with environment temperature 25 relative humidity 85 and vacuum degree is 0 1Mpa and all data has been tested with a mercurial thermometer to the...

Page 13: ...s and Conformity Construction in Accordance with the following Safety Standards UL 61010 1 2012 CSA C22 2 61010 1 12 2012 UL 61010 2 010 2015 CSA C22 2 61010 2 010 2015 Construction in Accordance with the following EMC Standards EN 61326 1 ...

Page 14: ...nsport In the event of identified damage please contact serviceusa hollandgreenscience com Note If you find any visible damage on the product please do not connect the product to power supply Type Item Description Quantity Main Unit Vacuum Oven 1 Fittings Vacuum Connection Pipe 1 Fittings Spanner 2 Quick Setup Card Scan to download user manual 1 ...

Page 15: ...key for 3s or more to control the run stop of the program 2 In the setup mode press this key to add one number and hold the key to increase numbers successively 3 In the setup mode press this key to decrease one number and hold the key to decrease numbers successively 4 Return 5 Set the target temperature and enter the internal parameter layers ...

Page 16: ... temperature F2 second layer measurement temperature F3 third layer measurement temperature F4 fourth layer measurement temperature RUN STOP display of running status 14 09 time display of controller system SET display of set value C display of temperature unit symbol ...

Page 17: ... will confirm this and after a 5 second self test is completed the temperature controller will automatically enter the run mode This will allow the PV screen to display the process temperature and the SV screen display the set temperature Once the process begins the AT indicator light will turn on and if process temperature is less than the set temperature heating lamps will turn on 7 5 Setting of...

Page 18: ...the key for 4 5 seconds Press key to confirm press or key to move press key to return TIMER WAIT ON OFF of waiting temperature When ON the waiting temperature is available When OFF no waiting temperature is available ALM Temp Setting of temperature deviation alarm when the measured temperature set temperature ALM TEMP an audible alarm will sound RH Temp Setting of the upper limit for Temperature C...

Page 19: ...ress key then shift the cursor to START SETUP and press key 1 START TIMER Press ON to start the Pre Set timer function settings 2 YEAR MONTH DAY HOUR MINUTE Enter timer pre set required details 7 9 Setting the ENGINEER SETUP Press and hold the key and press key then shift the cursor to ENGINEER SETUP and press key enter password The default is 0 and press to confirm Press key to move press key to ...

Page 20: ...sion 1 0 20 7 10 Unit SYSTM Timer and PASSWORD Settings Unit 0 1 YY year MM month DD day HH hour MM minute SS second this is the apparatus system time setting PASSWORD for direct input and changing of new password 0 1 ...

Page 21: ...ilter should be added in series before the vacuum intake If the air release rubber stopper becomes difficult to turn Vaseline may be used to lubricate the contact area The vacuum chamber should always be clean The glass on the cabinet door should only be cleaned using a soft cotton cloth Whenever the vacuum cabinet is not used for a prolonged period of time it is recommended that all exposed plate...

Page 22: ...emperature controller has no output Replace the temperature controller The heater is damaged short circuit or open circuit Replace the heater Timing function or the setting is not correct ST 0 or ST heating time constant temperature time Temperature Issues Out of Control Offset or Overshoot Error Display Tested Temperature vs Real Temperature The output of the temperature controller is unreliable ...

Page 23: ...r release valve and vacuum valve are not in the correct place Manually adjust positioning The electromagnetic valve is damaged Models 6090 6210 Replace electromagnetic valve Air Leakage Vacuum Degree Decreased to 0 092 Mpa from 0 1Mpa within 24 hours There is air leakage in various connect pipes and flanges Check all and replace if required Heat incurred from the oven can distort the shape of the ...

Page 24: ...or moist solids are spilled the vacuum oven please immediately disconnect the power supply and contact the service department Power must be disconnected before any maintenance or cleaning Surface stains on the vacuum oven should be cleaned only by a clean soft rag and detergent Keep the product clean and ensure no cleaning solution is spilled inside the vacuum oven Avoid cleaning the vacuum oven w...