background image

3

 

 

Model List view 

 

 

Model No. 

 

Description 

 

View 

Width 

Total Input 

BTU/hr 

Shipping 

Dimensions 

Crated 

Weight Lbs/Kgs 

 
 
BFR-24-4 

 
 
4 top burner 
range, one 
24” oven 

 

 

 
 
 

24” 

153,000/NG 

136,000/LP 

 

W27.5 X D36.6X 

H42.3 

366 / 166 

 
 
 
BFR-36-6 

 
 
6 top burner 
range, one 
36” oven 

 

 

 
 
 

36” 

213,000/NG 

190,000/LP 

 

W39.5 X D36.6X 

H42.3 

471 / 214 

 
 
 
BFR-60-10 

 
 
10 top burner 
range, two 
36” oven 

 

 

 
 
 

60” 

366,000/NG 

326,000/LP 

 

W63.5 X D36.6X 

H42.3 

764 / 347 

 
 
 
BFR-60-24G 
 

 
6 top burner 
range, one 
24” top 
griddle, two 
36” oven 

 

 

 
 
 

60” 

306,000/NG 

272,000/LP 

W63.5 X D36.6X 

H42.3 

817 / 371 

 
 
 

BFR-60-24TG 

 

6 top burner 

range, one 

24” top 

thermostat 

griddle, two 

36” oven 

 

 

 
 
 

60” 

306,000/NG 

272,000/LP 

 

W63.5 X D36.6X 

H42.3 

864 / 392 

 
 
 

BFR-60-24B 

 

6 top burner 

range, one 

24” top 

charbroiler 

two 36” oven 

 

 
 
 

60” 

316,000/NG 

288,000/LP 

 

W63.5 X D36.6X 

H42.3 

787 / 357 

Summary of Contents for BFR-24-4

Page 1: ...Rosecrans Ave Gardena CA 90248 USA Tel 1 866 677 8500 1 310 808 0102 Fax 1 310 808 0242 1 310 808 0262 WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DA...

Page 2: ...NSTALL GAS EQUIPMENT WHO SHOULD PERFORM THE INITIAL FIELD START UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE...

Page 3: ...D36 6X H42 3 471 214 BFR 60 10 10 top burner range two 36 oven 60 366 000 NG 326 000 LP W63 5 X D36 6X H42 3 764 347 BFR 60 24G 6 top burner range one 24 top griddle two 36 oven 60 306 000 NG 272 000...

Page 4: ...PPED FOR NATURAL GAS for conversion to LP gas please see gas conversion instruction manual attached Orifices necessary for LP propane natural conversion are provided Please refer to page 3 the orifice...

Page 5: ...ments do not agree do not proceed with the installation Contact your dealer or company immediately LOCATION The appliance must be installed under a ventilation hood The equipment area must be kept fre...

Page 6: ...lied by CHEF N SAVE that complies with the Standard for Connectors for Movable Gas Appliances ANSI Z21 69 CSA 6 16 and a quick disconnect device that complies with the Standard for Quick Disconnect De...

Page 7: ...rate instructions for installing casters to the range are included with the casters Note If the range is installed on casters and is moved for any reason it is recommended that the range be leveled fr...

Page 8: ...crating materials 2 Assemble the required components as shown in Fig s 2 and 3 and 4 3 Tighten the four screws to secure the shelf 4 Lift the assembly up sliding the channels into the space provided...

Page 9: ...9 5 Install four 10 sheet metal screws 2 to each channel leg Fig 6 LEVELING Check the leveling of the range Place a level inside the oven cavity across the Fig 5 Fig 6...

Page 10: ...e of obstructions Codes require that a gas shutoff valve be installed in the gas line ahead of the range Standard ranges are equipped with fixed burner orifices which coincide with installation elevat...

Page 11: ...leak limiter on gas pressure regulator as obstruction may cause regulator to malfunction WARNING PRIOR TO LIGHTING CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS USE SOAP AND WATER SOLUTION DO NOT...

Page 12: ...commended that the flue gases be ventilated to the outside of the building through a ventilation system installed by qualified personnel From the termination of the flue to the filters of the hood ven...

Page 13: ...be seasoned to do a good cooking job The metal surface of the griddle is porous Food tends to get trapped in these pores and stick therefore it is important to season or fill up these pores with cooki...

Page 14: ...or griddle top burner valve ON to remove air from the gas line Turn burner valve OFF when gas begins to flow Nightly Shutdown 1 Turn burner valve OFF pilot will remain lit Complete Shutdown 1 Turn bu...

Page 15: ...when gas begins to flow 9 Nightly Shutdown 10 Turn burner valve OFF pilot will remain lit 11 Complete Shutdown 12 Turn burner valve OFF pilot will remain lit 13 Turn main gas supply OFF OPEN TOP BURNE...

Page 16: ...ional models 1 Turn main gas supply ON Wait 30 seconds and using a taper light broiler griddle pilot 2 If pilot fails to light turn main gas supply OFF Wait 5 minutes and repeat Steps 1 and 2 3 Turn b...

Page 17: ...6 Replace lower panel 7 Turn thermostat to desired temperature 8 If the pilot becomes extinguished Wait 5 Minutes then repeat the above procedure Nightly Shutdown 1 Turn oven thermostat OFF Complete S...

Page 18: ...e knobs to full ON After preheating for 5 minutes turn valves down until desired flame or heating level is achieved Position the removable broiler grid into one of the two slide positions depending on...

Page 19: ...rning 1c Too much top heat a Insufficient ventilation b Improper fluing c Improper thermostat bypass setting d Thermostat out of calibration e Fluctuating gas pressure We all recognize however that re...

Page 20: ...tured by BLUE FLAME Products the products shall be free of defects in material or workmanship under normal and proper use and maintenance service as specified by BLUE FLAME Products and upon proper in...

Page 21: ...o event shall the user be entitled to recover incidental or consequential damages including but not limited to damages for inconvenience food loss rental or replacement equipment loss of profits or ot...

Page 22: ...y Units are shipped from the factory equipped for use on natural gas Parts necessary for L P liquid propane are provided with the unit Please refer to page 5 the orifice size list when you do gas conv...

Page 23: ...from half open to full open then screw in ensure fix well 13 1 Regulator convert for MR 6 GR24 G MR 6 GR24T G only Before installing the included convertible regulator unscrew the octagon cap You can...

Page 24: ...h gas conversion label on appliance the position below Gas conversion label The position for gas conversion 16 Completed gas conversion Pictured is the plastic insert Pull off insert from octagon cap...

Reviews: