Operating Instructions and Parts Manual

BCPA1

3

1.

 Status Light - See page 7 for  

    Light Blinking Pattern Definitions
2. 

Low Battery Light - See page 7 for  

    Light Blinking Pattern Definitions

GETTING TO KNOW YOUR  

ADVANCED TEXT NOTIFICATION 

DEVICE (FIGURE B)

                             Do NOT mix old and new 

                             batteries. Doing so will 

reduce overall performance and may cause 

battery leakage or rupture. When replacing 

batteries, always replace all 4 at the same 

time.

                             Using 3 or more batteries 

                             may appear to work 

properly even if one is inserted incorrectly. 

Such usage may lead to battery leakage 

or rupture that could result in equipment 

damage.

www.blueangelpumps.com/AdvancedText

                             Do NOT mix different 

                             battery brands or types. 

Doing so will reduce overall performance and 

may also cause battery leakage or rupture. 

We recommend using the same type of 

batteries within a device.

3. 

PUSH TO TEST - Sends a text 

    notification (up to 3) to all  

    emergency contact phone numbers 

    the home owner has programmed.
4. 

Lower Float Water Sensor Light

 

    This light blinks when the bottom 

    float is activated.
5. 

Upper Float Water Sensor Light - 

    This light blinks when  the top float 

    is activated.
6. 

Power Jack - A/C power adapter 

    plugs in here.
7. 

On/Off Switch - Turns the 

    Advanced Text Notification device 

    on or off.
8. 

Sensor Ports - The 2 dual 

    float sensors plug in here. See 

    (Figure B)

1

2

3

4

5

6

7

8

Figure B

Figure 1

                    

      Do NOT overtighten screws.

                    

      Use of this device and the  

                                  ability to send and receive 

texting alerts in the event of an emergency, are 

contingent upon an active cellular service.

STEP 1 - VERIFY PACKAGE  

CONTENTS

a.   Before installing your Advanced 

      Text Notification device, you will 

      need to check the signal strength/ 

      reception in your basement. To do 

      this, plug in the A/C power adaptor, 

      flip the “On/Off” switch to the “On” 

      position and wait for the status light 

      to change from a red light to a 

      blinking green light. Blinking green 

      indicates you have cellular 

      reception, (this can take up to 1 

      minute). 

b.   Next, flip the “On/Off” switch to 

      the “Off” position and unplug A/C 

      power. Remove (4) screws, lift lid 

      and install (4) AAA batteries. 

      (Figure 1) The negative (-) end of 

      the battery must touch the spring. 

      Replace the lid and (4) screws.

c.   Plug in A/C power adapter and flip 

      the “On/Off” switch to the “On”  

      position. Wait for the status light to 

      turn solid green indicating network 

      connection. 
NOTE: If the status light remains 

red, go online and check the Verizon 

wireless 3G coverage map:  

http://www.verizonwireless.com

OPERATING INSTRUCTIONS

STEP 2 

a. SIGNAL STRENGTH  

b. INSTALL BATTERIES 

c. NETWORK CONNECTION

Summary of Contents for BCPA10

Page 1: ...ol unit that attaches to the discharge pipe above the pit and a power cord When the device detects a power outage or high water condition a LED light flashes an audible alarm sounds and the device wil...

Page 2: ...perating technique that is not specifically recommended by Blue Angel Pumps is used you must satisfy yourself that it is safe for you and for others You should also ensure that the product will not be...

Page 3: ...Sensor Light This light blinks when the top float is activated 6 Power Jack A C power adapter plugs in here 7 On Off Switch Turns the Advanced Text Notification device on or off 8 Sensor Ports The 2 d...

Page 4: ...Figure 5 NOTE The status light should now be solid green Use above a completely enclosed sump pit www blueangelpumps com AdvancedText You will receive 2 emails 1 A receipt for your credit card purchas...

Page 5: ...e service has been interrupted or disconnected or the phone is off it will NOT receive an alert text notification The device will send alerts to all of the phone numbers that have been saved to Phone1...

Page 6: ...PDATE OPTIONAL USER COMMANDS HOW TO CHANGE A PHONE NUMBER DEVICE INTERACTION You can also text settings to the device and it will respond with a text message with the current settings stored in the de...

Page 7: ...er detected Operating Instructions and Parts Manual BCPA1 7 www blueangelpumps com AdvancedText Your unit will warn you when there is a problem detected Use the chart below to determine your audible a...

Page 8: ...t is adjacent to soil The status light is flashing red quickly An error has occurred Power off the Advanced Text Notification device for 10 seconds and then power it back on The low battery light is f...

Page 9: ...signal strength Cellular network congestion Locate the Advanced Text Notification device to an area with better cellular reception No remedy The Advanced Text Notification device is not communicating...

Page 10: ...None 100 dB to 113 dB WEAK Make sure device is not near foundation wall or an area that can restrict cellular signal Move to another location where better cellular signal is available 113 dB NONE The...

Page 11: ...Operating Instructions and Parts Manual BCPA1 11 NOTES www blueangelpumps com AdvancedText...

Page 12: ...ES OR EXPENSES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages s...

Reviews: