Operating Instructions and Parts Manual
BCPA1
8
All of the lights
are flashing on
and off and the
device keeps
beeping
The backup batteries
are too low to power
the Advanced Text
Notification device
Replace the backup batteries
Use only alkaline batteries.
Do not use “heavy duty”
batteries
www.blueangelpumps.com/AdvancedText
Troubleshooting Guide
Message
Possible Cause(s)
Corrective Action(s)
Status light is on
solid red
Insufficient cellular
signal strength
Locate the Advanced Text
Notification device to an area
with better cellular reception,
away from metal objects, or
higher elevation
Locate the Advanced Text
Notification device to an interior
wall, away from a wall that is
adjacent to soil
The status light
is flashing red
quickly
An error has occurred
Power off the Advanced Text
Notification device for 10
seconds and then power it
back on
The low battery
light is flashing
even though I
replaced the
batteries
The batteries are not
installed properly
You are using low
quality batteries
You did not power off
the Advanced Text
Notification device
before replacing
batteries
Ensure the polarity of the
batteries are correct. The
negative (-) end of the battery
touches the spring in each
holder
Use only alkaline batteries. Do
not use “heavy duty” batteries
Power off the Advanced Text
Notification device for 10
seconds and then power it
back on
The Advanced
Text Notification
device is
chirping every
30 seconds
The backup batteries
are low
Replace the backup batteries
Use only alkaline batteries.
Do not use “heavy duty”
batteries
TROUBLESHOOTING