Operating Instructions and Parts Manual

BCPA1

10

www.blueangelpumps.com/AdvancedText

For Replacement Parts or Technical 

Assistance, call 888-636-6628

Please provide following information:

  - Model number

  - Unit ID

  - Part description and number as shown 

       in parts list

Address parts correspondence to:

Blue Angel Pumps

101 Production Drive

Harrison, OH  45030 U.S.A.

Ref. No.

Description 

Part No.

Quantity

1

A/C Power Adapter

66340-001

1

2

Dual Float Sensor  

with Hose Clamp

60158-002

1

1

2

Signal Strength Guide 

Where Signal is

Status

Corrective Action(s)

-40 dB to -99 dB 

OK

None

-100 dB to -113 dB

WEAK

Make sure device is not near

foundation wall or an area that

can restrict cellular signal. Move

to another location where better

cellular signal is available

> -113 dB

NONE

The device is not able to send or

receive alert messages. Move

device to a location that can

connect with the cellular towers

NOTE: In some cases it will be necessary to note the signal strength/reception in 

your basement to install or activate the device. Below are the ranges of cellular 

signal strength you may encounter (in dB) during setup. If there is a problem 

connecting to the network, or the device will not stay connected, refer to the 

chart below to diagnose the problem.

Recommended signal range for optimal performance should be between -40 dB 

and -99 dB. 

Summary of Contents for BCPA10

Page 1: ...ol unit that attaches to the discharge pipe above the pit and a power cord When the device detects a power outage or high water condition a LED light flashes an audible alarm sounds and the device wil...

Page 2: ...perating technique that is not specifically recommended by Blue Angel Pumps is used you must satisfy yourself that it is safe for you and for others You should also ensure that the product will not be...

Page 3: ...Sensor Light This light blinks when the top float is activated 6 Power Jack A C power adapter plugs in here 7 On Off Switch Turns the Advanced Text Notification device on or off 8 Sensor Ports The 2 d...

Page 4: ...Figure 5 NOTE The status light should now be solid green Use above a completely enclosed sump pit www blueangelpumps com AdvancedText You will receive 2 emails 1 A receipt for your credit card purchas...

Page 5: ...e service has been interrupted or disconnected or the phone is off it will NOT receive an alert text notification The device will send alerts to all of the phone numbers that have been saved to Phone1...

Page 6: ...PDATE OPTIONAL USER COMMANDS HOW TO CHANGE A PHONE NUMBER DEVICE INTERACTION You can also text settings to the device and it will respond with a text message with the current settings stored in the de...

Page 7: ...er detected Operating Instructions and Parts Manual BCPA1 7 www blueangelpumps com AdvancedText Your unit will warn you when there is a problem detected Use the chart below to determine your audible a...

Page 8: ...t is adjacent to soil The status light is flashing red quickly An error has occurred Power off the Advanced Text Notification device for 10 seconds and then power it back on The low battery light is f...

Page 9: ...signal strength Cellular network congestion Locate the Advanced Text Notification device to an area with better cellular reception No remedy The Advanced Text Notification device is not communicating...

Page 10: ...None 100 dB to 113 dB WEAK Make sure device is not near foundation wall or an area that can restrict cellular signal Move to another location where better cellular signal is available 113 dB NONE The...

Page 11: ...Operating Instructions and Parts Manual BCPA1 11 NOTES www blueangelpumps com AdvancedText...

Page 12: ...ES OR EXPENSES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages s...

Reviews: