background image

CLEANING INSTRUCTIONS 

PROCEDURE:  Clean Coffee Brewer

 

 
PRECAUTIONS:    Disconnect brewer from electric power.  
                               Allow brewer to cool. 
 
FREQUENCY:       Daily 
 
TOOLS:                  Mild Detergent, Clean Soft Cloth or Sponge 
                               Bristle Brush. 
 
 
1.    Disconnect brewer from electric power.  
       Allow brewer to cool before cleaning. 

 

2. Remove and empty decanters. 

 

3. Remove and empty brew chamber. 

 

4. Remove the spray disk from the brew head (See figure 6): 
       Press up on the spray disk ears, then turn the disk to the left 
       to unlatch.  Remove the gasket from inside the brew head. 

 

5.    Wipe inside of brew head and area around the brew head 
       with a soft clean cloth or sponge moistened with clean water. 

 

6.    Wash the spray disk in a sink using warm water and a mild 
       detergent.  A bristle brush may be used to clear clogged 
       spray holes.  Rinse the spray disk with clean water and allow 
       to air dry. 

 

7.    Wash the brew chamber in a sink using warm water and a 
       mild detergent.  A bristle brush may be used to clean the   
       inside. Rinse with clean water and allow to air dry.  For 
       stainless steel brew chambers, be sure the wire rack is    
       properly reinstalled. 

 

8.    Wipe the exterior of the brewer with a soft clean cloth or 
       sponge moistened with clean water. 

 

10. Reinstall the gasket 

INSIDE

 the brew head, then reinstall the 

       spray disk. 

 

11. Reinstall the brew chamber. 

 

12. Remove stopper assembly from airpot: 
       a.     Airpots may be washed by filling with warm soapy water  
               and cleaned with a bottle brush.  
               IMPORTANT:  DO NOT submerge airpots in water. 
       b.     Stopper assembly may be washed in a sink with warm     
               soapy water.  
       c.     Rinse airpot and stopper thoroughly with clean warm       
               water     and allow to air dry . 
 
 
Procedure is complete 

CAUTION: 
Burn Hazard 
 

Brewing and serving 
temperatures of coffee are     
extremely hot. 
Hot coffee will cause 
serious skin burns. 
 

 

CAUTION: 
Electric Shock  
Hazard 

Do not submerge or immerse 
brewer in water.   
 

IMPORTANT: 

DO NOT use steel wool, sharp 
objects, or caustic, abrasive or 
chlorinated cleansers to clean 
the brewer. 

Fig. 6  Cleaning 

Summary of Contents for Aquarius 8382

Page 1: ...p n 75611 Rev E ECN 12597 M682 040914 cps 682 OWNERS MANUAL for BOTTLED WATER AIRPOT COFFEE BREWERS MODEL 8382 for 3 Gallon and 5 Gallon Plastic Bottles Includes Installation Operation Use Care Servi...

Page 2: ...f its sub agencies This service will be provided on customer s premises for non portable models Portable models a device with a cord and plug must be taken or shipped to the closest Authorized Service...

Page 3: ...r and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES OPERATING CONTROLS 2 PRECAUTIONS GENERAL INFORMATION 3 AGEN...

Page 4: ...FEATURES AND OPERATING CONTROLS 2 Fig 1 Features Operating Controls...

Page 5: ...agents This appliance is intended for use in commercial establishments where all operators are familiar with the appliance use limitations and associated hazards Operating instructions and warnings mu...

Page 6: ...2 is equipped with a cord and plug It requires a 115 125 volt 20 amp circuit 50 60 Hz 2 wire plus ground with NEMA 5 15R or 5 20R Receptacle IMPORTANT Supply power must match nameplate for voltage and...

Page 7: ...equate amount of water in place will produce very little or no brewed coffee IMPORTANT When installing water bottle be careful to not overflow the basin pan DO NOT fill the basin pan prior to installi...

Page 8: ...ed to the hot water tank by a bottle inserted in the bottle ring Water will flow from the bottle into the basin pan until the water level reached the open mouth of the bottle Pressing BREW button ener...

Page 9: ...brew may lower the temperature of the brew water PREPARATION Place one 1 genuine Bloomfield paper filter in the brew chamber Add a pre measured amount of fresh coffee grounds Gently shake the brew cha...

Page 10: ...rm water and a mild detergent A bristle brush may be used to clean the inside Rinse with clean water and allow to air dry For stainless steel brew chambers be sure the wire rack is properly reinstalle...

Page 11: ...brewer 7 Wash the basin pan and bottle ring with a clean cloth and mild detergent 7 Soak the basin pan basin seal and top panel in sanitizer per the directions supplied with the sanitizer 8 Rinse the...

Page 12: ...SIBLE CAUSE Brewer unplugged or circuit breaker tripped Thermostat set too low Hi Limit thermostat tripped Damaged internal component or wiring Water bottle empty Too much coffee grounds Timer out of...

Page 13: ...e Upon completion reinstall top panel CAUTION Electric Shock Hazard Opening access panels on this brew may expose uninsulated electrical components Disconnect brewer from electrical power before remov...

Page 14: ...ker OFF Remove water bottle Run water from the hot water faucet until no more water flows Remove top panel Siphon water from the tank through the faucet supply fitting until the water level in the tan...

Page 15: ...connections Remove wiring connections from solenoid coil Remove solenoid Reassemble in reverse order REPLACE TIMER ASSEMBLY Unplug power cord or turn circuit breaker OFF Remove front panel Remove knob...

Page 16: ...Brush Large Sink or other appropriate work area 1 Disconnect brewer from the electrical supply Remove the water bottle and drain the tank by running water from the hot water faucet until no more wate...

Page 17: ...Verify that all internal components are dry then reinstall the top panel 10 Reconnect brewer to electrical supply 11 Install the brew chamber without filter paper or grounds Run at least three full b...

Page 18: ...o install 1 40 8810 70 RESTRICTOR BREW NOZZLE 1 41 83384 TUBE FAUCET SUPPLY METAL 1 42 85609 INSERT BREW OUTLET ELBOW 1 43 82241 FITTING BARBED BRASS 1 45 83388 SOLENOID BREW 120V 1 46 85634 TUBE BREW...

Page 19: ...ATOR LIGHT GREEN 120V 1 35 8812 61 TIMER 8 MIN 1 36 6407 15 POWER CORD NEMA 5 15P 1 36t 8552 18 TERMINAL BLOCK 4P 1 37 51217 STRAIN RELIEF 90 CLAMP 1 45 83388 SOLENOID BREW 120V 1 50 86280 THERMOSTAT...

Page 20: ...SHING SHORTY HEYCO 2 78 8810 12 BUTTON PLUG 7 8 DIA 2 80 85583 BOTTLE RING Model 8382 1 80x 3300 BOTTLE RING OASIS Model 8382OR 1 81 85619 LABEL 1 101 BASE BODY ASSEMBLY 1 102 BASE FRONT PANEL 1 104 B...

Page 21: ...WIRING DIAGRAM 19...

Page 22: ...c Division of Carrier Commercial Refrigeration In US and Canada Telephone 775 689 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com for orders only Bloomfield Industries proudly s...

Reviews: